Showing: 1 to 10 of 33 matches for "fan silencer construction"  Page   1   2   3   4
TITLE Noise Suppression by Flexible Fan Silencers 
SUMMARY ... Silencers: There are three main components of any type of fan silencer: the outer
shell, the dampening material, and ... Figure 2. Flexible silencer construction ...
AUTHOR Partyka, J. ; Kelly, Trevor R. J.
PUBLISHED 1995
TITLE Part 7: Noise Investigation and Reduction 
SUMMARY ... 1446. Actual octave band spectral analysis of 6-ft (1.8-m) diam axial fan. Page
8. ... (125 x 9.5-mm) refuse. The original chute was all welded steel construction. ...
AUTHOR Chedgy, David G.
PUBLISHED 1991
TITLE Noise Reduction in Compressed Air Driven Fans 
SUMMARY ... inlet was connected to the CC fan it caused a ... that each extension advanced around
the silencer into the ... drag coefficient was reduced with the construction of a ...
PUBLISHED 1973
TITLE Ventilation Design for Yucca Mountain Exploratory Studies Facility 
SUMMARY ... Construction schedule has prioritized the subsurface loop connection of the North
and South Ramp ... operational safety; (e) Fan silencer not to exceed 1,753 mm ...
AUTHOR Jurani, Romeo S., P. E.
PUBLISHED 1995
TITLE Coal Mine Ventilation Returns to Centrifugal Fans 
SUMMARY ... All-steel construction. High-strength, low- ... Close running clearance on rotor-to-casing
or a silencer can be fitted. ... FIG. 2 Degas hole centrifugal fan. ...
AUTHOR Gutzwiller, Les
PUBLISHED 1999
TITLE Topics of Special Interest 
SUMMARY ... plant, various state and federal permits must be obtained, such as construction
permits and ... emanating from the drive motor is due to its cooling fan which may ...
AUTHOR Wheelock, T. D. ; Chedgy, D. G. ; Muter, R. B. ; Grady, W. C.
PUBLISHED 1979
TITLE A Common Sense Approach To Control Of Construction Noises In Urban Areas 
SUMMARY ... 1 tunnel ventilation fan without a silencer and 2 unscheduled air ... GENERAL BACKGROUND
Since rapid rail transit construction began in Washington, DC ...
AUTHOR Lynch, Frank L. ; Knight, Kenneth G.
PUBLISHED 1974
TITLE Soft Ground Tunnelling On Staten Island 
SUMMARY ... Both alternatives required construction of a major lift station at ... Our bids
were based on use of the following general construction ...
AUTHOR Wagner, John R. ; White, Christopher P.
PUBLISHED 1991
TITLE Adding a third main fan at the Waste Isolation Pilot Plant 
SUMMARY ... authorizing construction and development of the WIPP ... system effi- ciency (with the
new fan in parallel ... silencer and discharge evase, is 69.5% in normal mode ...
AUTHOR McDaniel, K. H. ; Griswold, L.
PUBLISHED 2000
TITLE Ventilation planning at Energy West?s Deer Creek Mine 
SUMMARY ... and design shall minimize the construction area required ... the cost and pressure loss
of an inlet silencer. ... suppression – The suppression of the fan sound was ...
AUTHOR Tonc, L.
PUBLISHED 2009
Showing: 1 to 10 of 33 matches for "fan silencer construction"  Page   1   2   3   4