Register  
Forgot Password?
Forgot User Name?
 

Search Results

Search Results for "main fan noise"

  Search Again
Organization / Society
AIME (76)
AUSIMM (94)
DFI (4)
NIOSH (211)
RMCMI (16)
SAIMM (16)
SME (208)
TMS (2)
USBM (1)



Showing: 1 to 10 of 628 matches for "main fan noise"  Page   1   2   3   4   5   6   7   8   9  next
TITLE Site Determination Of Properties Of Main Fan In Mine Shaft 
SUMMARY ... 2. The determination of revolution of main fan, noise and parameters of atmosphere
For rectifying the determined curve of properties under the rated revolution ...
AUTHOR Shuguang, Jiang ; Huicheng, Zhang ; Xingshen, Wang
PUBLISHED 1991
TITLE Noise Assessment Of Stone/Aggregate Mines: Six Case Studies 
SUMMARY Page 1. Noise assessment of stone/aggregate mines: ... BAIIH number of ways, including
condnct- Exposure tq noise and noisefa- ing a cross-sectional survey of noise ...
AUTHOR Bauer, E. R. ; Babich, D. R.
TITLE Preliminary Ventilation Design ù Ballarat Goldfields 
SUMMARY ... to be applied: 1. Main fans are to be sited underground to reduce noise pollution
as ... 4. The main fan must be of a size that fits in a standard airway size and ...
AUTHOR R Nakia ; R Livingstone
PUBLISHED 2003
TITLE Mine Ventilation at Kiruna 
SUMMARY ... Fig.5). It,too,is equipped with noise silencers and is designed to minimize the
noise impact on ... 5 Schematic of the main fan station KV10-12 in the Kiruna Mine. ...
AUTHOR Mukka, Lennart
PUBLISHED 2002
TITLE Differences In Design Considerations For Tunnel Vs. Mine Ventilation Fan Systems -Preprint 09-056 
SUMMARY ... US require a standby fan powered by a diesel generator for each main mine fan ... the
operating flow and pressure design duty point to determine the fan noise level ...
AUTHOR Gamble, G. A.
PUBLISHED 2009
TITLE Technical Papers - Breaking The Ice On The Booster Fan Dilemma In US Underground Coal Mines 
SUMMARY ... It was also noted that the booster fan would be located in a main return, away from
the working face and, thus, dust and noise were not considered to be a ...
AUTHOR Martikainen, A. L.
PUBLISHED 2010
TITLE Ventilation planning at Energy West?s Deer Creek Mine 
SUMMARY ... The operating point of the Deer Creek Fan located at the main entrance to ... site is
very difficult considering the unknown interaction of the fan noise with the ...
AUTHOR Tonc, L.
PUBLISHED 2009
TITLE Ventilation and Cooling Design for Long Declines 
SUMMARY ... Noise • 85 dBA continuous exposure. ... Electric power, installed main fan costs and
maintenance are taken as $A 0.06/kWh, $A 1200/kW and 15 per cent of the ...
PUBLISHED 2005
TITLE Extension of the main ventilation system at LKABs Kiruna Mine for the new main haulage level 1365 m 
SUMMARY ... Main Ventilation System ... See Figure 3. Because the fan stations KV 10/12 and 15/20
are ... and the town, they have been equipped with silencers for noise reduction. ...
AUTHOR Mukka, L.
PUBLISHED 2009
TITLE The Underground Main Fan Study at the Waste Isolation Pilot Plant 
SUMMARY ... A similar fan system equipped with lVCs also satisfied all ... Noise level was also of
concern in that there are numerous offices in the vicinity of the main fans. ...
AUTHOR McDaniel, Kirk H. ; Chmura, K. M. (Chris) ; Wallace, Keith G.
PUBLISHED 1997
Showing: 1 to 10 of 628 matches for "main fan noise"  Page   1   2   3   4   5   6   7   8   9  next

Search Again