Air Quality Control In Diesel Equipment Operations At The Henderson Mine ? Introduction

- Organization:
- Society for Mining, Metallurgy & Exploration
- Pages:
- 6
- File Size:
- 310 KB
- Publication Date:
- Jan 1, 1980
Abstract
The mine ventilation system of the Henderson Mine provides a case study of designing and maintaining high-quality respirable air in a large underground mine with over 200 units of diesel-powered equipment. This system was designed with concern for minimizing exposure to personnel of siliceous dust, diesel exhaust, smoke, and potential fire hazards while optimizing general environmental air quality throughout the multilevel/multiheading operation. As a relatively new operation, the Henderson Mine incorporates a modern ventilating plant and mine de- sign as well as state-of-the-art technology where appropriate. Two main ventilation shafts approximately 2,300 ft (701 m) in depth (one intake, one exhaust) will handle 1.8 million cfm (850 m3/s) of air circulated throughout 60 miles (97 km) of drifting, providing the ventilation requirements for more than 25,000 diesel horsepower (18,642 kw) underground.
Citation
APA:
(1980) Air Quality Control In Diesel Equipment Operations At The Henderson Mine ? IntroductionMLA: Air Quality Control In Diesel Equipment Operations At The Henderson Mine ? Introduction. Society for Mining, Metallurgy & Exploration, 1980.