Abstract
The use of controlled recirculation can be dated back to the early 1930s. Although this method has been applied in many mines since then, a generalized comprehensive network analysis is still lacking. This paper presents a unique approach in which the ventilation network with a controlled district recirculation is divided into two subsystems: a main subsystem and a recirculation subsystem. The subsystems are analyzed individually and the results and their relationships are then integrated into discussions of the total ventilation system. The analysis of the recirculation subsystem is facilitated by introducing a non-dimensional parameter A, which represents the ratio of the air quantity for the working face to that for the subsystem. As a result, fan and regulator pressures and air power for various recirculation arrangements can be effectively expressed as a function of A and the subsystem air quantity. Numerical examples are included.
Citation
APA: (1995) An Analysis Of Controlled District Recirculation System
MLA: An Analysis Of Controlled District Recirculation System. Society for Mining, Metallurgy & Exploration, 1995.