Assuming a number of discrete leakage paths and treating the airflow through leaky duct line as a series-parallel combination of airflows along the duct and through leakage paths, exact solutions for auxiliary ventilation problems can be obtained. A computer program "SEGMENT'' has been written to solve problems using this method. However, most of the investigators have treated the duct lines with a uniformly distributed leakage and many have derived formulas assuming various boundary conditions and levels of simplification for the design of a simple auxiliary ventilation system An appraisal of accuracy of the various formulas has been conducted using the results from the program "SEGMENT' as benchmark and the formulas which give accurate results have been identified. The ranges of application for all the formulas have also been determined for 5 %error.