Abstract
A cover with capillary barrier effects (CCBE) is being constructed on the AA Leach Pad at the Barrick Goldstrike Mine site near Carlin, Nevada. The purpose of the cover is to eliminate/minimize infiltration of meteoric waters into the leach pad. Laboratory and numerical analyses indicate that Carlin Formation siltstone (TCS), a locally available material, has the necessary hydrologic characteristics when placed on the leach pad to act as a CCBE. A pilot study has been conducted on a small-scale test cover placed on the AA Leach Pad to examine the cover performance under irrigated conditions. The preliminary test results demonstrate that the designed cover is capable of preventing meteoric water infiltration.