Coal - Bituminous Coal Electrokinetics

The American Institute of Mining, Metallurgical, and Petroleum Engineers
John A. L. Campbell S. C. Sun
Organization:
The American Institute of Mining, Metallurgical, and Petroleum Engineers
Pages:
4
File Size:
873 KB
Publication Date:
Jan 1, 1971

Abstract

The surface properties exhibited by bituminous coal and bituminous coal lithotypes were ascertained by using streaming potential techniques. The electro kinetic prop-erties wereascertainederties of bituminous coal were found to be similar to those of anthracite. The principle electrokinetic properties of the coal and lithotypes, zero-points-of-charge (ZPC), and potential determining ions, were established. The effects of indifferent electrolytes, hydronium and hydroxyl ion sources, and polyvalent ions (cationic and anionic) were also evaluated. Location of the ZPC's with respect to pH is discussed in terms of chemical and mineralogical composition of the respective surfaces. To account for the observed electrokinetic phenomena, a generalized surface model and adsorption mechanism are proposed. Surface-dependent processes, such as froth flotation and flocculation, are important or potentially important techniques for combating some of the current major problems in coal preparation. In order to correctly apply or improve a surface-dependent process, it is of paramount importance to understand the interfacial phenomenon, especially the double layer properties, exhibited by the solid. The specific objective of this research was to determine the properties of the bituminous coal/liquid interface by an electrokinetic method, streaming potential, and to relate the findings, wherever possible, to the existing unit operations of froth flotation and floccula-tion tion. The electrokinetic properties of both the whole coal and its lithotypes were investigated. As part of the total investigation, the role played in the double layer by the reagents commonly employed in the surface dependent process was also established.' These data will be presented at a later date. Experimental Procedures The coal samples used in this research and their designations are listed in Table 1. The classical description of humic coal lithotypes as developed by Stopes" was used for the delineation of the lithotype samples. The samples were taken from the working face of a producing deep mine of the Pittsburgh seam in the area of Ellsworth, Pa. To avoid oxidation, only freshly exposed areas were sampled. The normal precautions against contamination were also exercised. Two types of samples were taken, specimens rich in a particular lithotype and a representative channel sample. The latter sample was prepared for analyses by grinding it to —35 mesh. It was screened repeatedly during the grinding to provide the largest amount of 35 x 48-mesh (standard Tyler sieves) material possible. The screened fraction was passed over a magnet and then washed several times with distilled water and finally with conductivity water. The resulting sample now termed "whole coal" was stored under conductivity water in a glass bottle. Pure lithotypes were obtained from the lithotype concentrates by hand picking, and were processed in the same manner as the representative sample. Maceral analyses, employing standard petrographic procedures," were performed on the lithotype samples to determine the purity of the samples. The results are presented in Table 2. Reflectance measurements of the vitrinites and fusinites are also reported in this table. Proximate and ultimate analyses of the samples are given in Tables 3 and 4. The electrokinetic properties of the coal samples were determined by streaming potential methods.'-' All of the chemicals used in the investigation were reagent grade (Baker analyzed). The conductivity water was prepared by doubly distilling the water in a pyrex Yoe-type still and passing the distillate through a mixed bed ion exchange column. Results In general, the electrokinetic properties of the investigated bituminous coal were found to be similar to the results of a previous study of anthracite by Camp-bell bell5 and are in accord with the suppositions of Brown." The zeta potentials of the coal and all the lithotypes were found to be negative in conductivity water. Jowett? in a study of slime coatings on coal also found bituminous coal to exhibit a negative surface. Fig. 1 shows that the negative charges, at neutral pH's, for both fusain and the gangue are very small, almost zero, while at the same pH, vitrain has the largest negative charge, almost 30 mv. Durain has a negative charge of 17.5 mv. The determination of the affect of pH on the charge of the coal surfaces revealed that hydronium and hydroxyl ions apparently behave as potential determining ions; however, they do not appear to be potential determining for the gangue. These results are illustrated in Fig. 1. As the pH of the solution was decreased, hydronium ions were adsorbed, causing the surface of the coal to reverse polarity and become
Citation

APA: John A. L. Campbell S. C. Sun  (1971)  Coal - Bituminous Coal Electrokinetics

MLA: John A. L. Campbell S. C. Sun Coal - Bituminous Coal Electrokinetics. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1971.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account