Conductance Electrostatic Separation with Convective Charging

The American Institute of Mining, Metallurgical, and Petroleum Engineers
Foster Fraas Oliver C. Ralston
Organization:
The American Institute of Mining, Metallurgical, and Petroleum Engineers
Pages:
3
File Size:
239 KB
Publication Date:
Jan 10, 1950

Abstract

VIRTUALLY all commercial use of electrostatic separation has employed separators depending on differences of conductance of the broken, solid mixtures treated by them. The two main types of conductance separators have been: (1) Those in which the separating field is as near a static field between two charged electrodes as it is possible to maintain in the face of the usual leakage that takes place between electrodes with some 5 to 50 kv tension between them and spacing of l/z to 3 in.; (2) those in which a convective discharge of corona or spray type, but not a spark discharge, takes place between the carrier electrode and a charged electrode facing it, which is of very restricted area, such as a row of needle points or a small diameter wire parallel to the face of the carrier electrode. The present paper deals with this latter type. The principle is usable in separators where the carrier electrode, usually grounded, has the shape of a roller, a conveyor belt, a vibrating table, a sloping chute, or a nearly vertical plate. The innovation studied by us has been the use of the convective field for charging material on the carrier electrode and succeeded by a field between the carrier electrode and an electrode made of a true dielectric which cannot take on a charge by conduction but is charged by being in the radius of the corona discharge. The acquired charge is of the same sign as that of the corona but is not dischargable by contact with a good conductor. However, high-tension charge tends to leak off because of the ionization of the ambient air. The field between this electrode and the carrier electrode is as near static as it is possible to obtain. There are some differences in behavior of this electrode and that of the gas tube electrode used by Sutton, as will be discussed below. Both electrodes cause increased adhesion of nonconductive particles to the carrier roll. The particles are pinned there because they are convectively charged on their outer surfaces facing the corona electrode. The electrodes also cause increased rate of release of conductive particles tending to be pinned by corona charging but conveying the charge to the grounded carrier roll almost as rapidly as it is received by the particles.
Citation

APA: Foster Fraas Oliver C. Ralston  (1950)  Conductance Electrostatic Separation with Convective Charging

MLA: Foster Fraas Oliver C. Ralston Conductance Electrostatic Separation with Convective Charging. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1950.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account