Cooling innovation in practice: A case study on composite copper-graphite cooler performance before and after a PGM furnace partial sidewall rebuild
- Organization:
- The Southern African Institute of Mining and Metallurgy
- Pages:
- 7
- File Size:
- 2665 KB
- Publication Date:
- Mar 6, 2026
Abstract
Sibanye-Stillwater recently completed a partial sidewall rebuild on Furnace 1 at its Marikana
smelter complex. The project involved matte taphole maintenance, which required the removal
and subsequent replacement of 18 composite copper-graphite coolers and a section of the
lower refractory sidewall. These composite copper-graphite coolers are a newly developed
cooling design by Tenova Pyromet, and this rebuild project provided valuable insight into the
performance of the composite coolers. The novel composite cooler design was implemented to
serve as a safeguard against localised wear and corrosion in the furnace sidewall, particularly
at the slag-concentrate interface, where chloride-accelerated sulphidation has been identified
as a dominant degradation mechanism affecting the copper cooling elements. The composite
cooler design is unique in that all the exposed sides of the water-cooled copper elements are
fully encapsulated in graphite, which protects the copper from corrosive sulphur- and chlorinebearing
gases and condensates. This sidewall cooling system was designed to improve corrosion
resistance, stabilise freeze lining formation, and extend the campaign life of the furnace sidewall.
The partial sidewall rebuild was executed during a planned maintenance shutdown with the
main objective of replacing the matte taphole lintel bricks. This paper serves as a case study that
compares and evaluates the operational performance of the composite coolers before and after
the rebuild. The installation method is discussed to highlight the approach taken to ensure a
sound installation while minimising downtime, as well as to present some lessons learned in
the process.