Core Analysis - The Kobe Porosimeter and the Oilwell Research Porosimeter

The American Institute of Mining, Metallurgical, and Petroleum Engineers
Carrol M. Beeson
Organization:
The American Institute of Mining, Metallurgical, and Petroleum Engineers
Pages:
6
File Size:
476 KB
Publication Date:
Jan 1, 1950

Abstract

Reasons are given for using a Boyle's-law porosimeter in conducting core analysis for either routine or research purposes. Among other things, it is pointed out that such a porosimeter permits the measurement of all basic properties on the same sample, thereby eliminating the sources of error inherent in the use of adjacent samples. References are made to investigations of gas adsorption on various porous materials, to show that the use of helium in Boyle's-law porosimeters reduces to negligible proportions the error due to the adsorption or desorption of the operating gas. Two Boyle's-law instruments are described. which permit accurate and rapid measurements of porosity. Schematic sketches and explanation:; are included, along with derivations of equations required in performing precise determinations. Summaries of data obtained during calibration are tabulated and analyses of the data are resented as indications of the precision and accuracy of each device. Comparisons are also shown for measurements made with each of the instruments on the same test pieces and cores. INTRODUCTION An accurate porosimeter, operating on the principle of Boyle's law. is of considerable value in the analysis of cores for either routine or research purposes. This is due primarily to the fact that the measurement of porosity with such an instrument leaves the sample free of contamination by any liquid. When used in conjunction with an extraction apparatus' for determining oil and water saturations, a Boyle's-law porosimeter permits the measurement of all basic properties on the same sample. This eliminates the sources of error inherent in the use of adjacent samples, or the necessity of determining porosity after all other properties have been obtained. Large errors may result from combining measurements made on adjacent samples in order to obtain a single property. This type of error is definitely involved when oil and water are measured with one sample, and the pore vo1ume is measured with an adjacent one. Furthermore, the source of error would be present to some extent, even if the analyst could choose the samples so they were truly adjacent from a geological standpoint. The use of adjacent samples in routine core analysis also necessarily decreases the probability of correlating core properties. For example, the chance of correlating the "irreducible" interstitial-water saturation with permeability, is bound to be greatly reduced by measuring these properties on "adjacent" samples. For research purposes, amplification is scarcely required concerning the greater flexibility of a method for measuring porosity which leaves the core free of contamination by any liquid. Even under those circumstances which require that the core be saturated with a liquid, a previous measurement of porosity with a gas is useful in determining the degree of saturation that has been attained in the process. Furthermore, for comparable accuracy, porosity usually may be determined more rapidly with a gas than with a liquid. This advantage of the Boyle's-law instrument is most outstanding when the determination time is compared with that required in obtaining porosity by evacuation of the core followed by saturation with a liquid of known density. Several porosimeters which operate on the principle of Boyle's law have been described2,3,4,5,6,7 in the literature. No comparison will be attempted between those instruments and the ones described herein. Before helium gas became readily available, Boyle's-law porosimeters were subject to an appreciable error due to the adsorption of the operating gas on the surface of the core solids. There is considerable direct and indirect evidence in the literature to support the contention that the adsorption of helium on porous solids is negligible at room temperature. In discussing the use of Boyle's-law porosimeters, Washburn and Bunting2 stated that "for most ceramic bodies dry air is a satisfactory gas, but hydrogen will be required in some instances. Helium could, of course, be employed for all types of porous materials at room temperatures or above." Howard and Hulett8 obtained evidence that the adsorption of helium was negligible at room temperatures, even on activated carbon ; for the density measured with this gas was unaffected by changes in pressure or by changes in temperature from 25 °C to 75 °C. For oil-well cores, Taliaferro, Johnson, and Dewees" obtained lower porosities with helium than with air, but apparently did not study helium adsorption. From the work of these investigators, it follows that the use of helium in Boyle's-law porosimeters reduces the error due to gas adsorption to negligible proportions. This makes it possible to construct instruments which permit the determination of porosity with (1) a high degree of accuracy, (2) with great rapidity, and (3) without contamination. THE KOBE POROSIMETER The fundamental design of the Kobe Porosimeter was developed by Kobe, Inc., which firm built about 12 of the instruments during 1936 and 1937. Since that time, seven or eight more have been constructed with their permission, making a total of about 20 that have been put into operation.
Citation

APA: Carrol M. Beeson  (1950)  Core Analysis - The Kobe Porosimeter and the Oilwell Research Porosimeter

MLA: Carrol M. Beeson Core Analysis - The Kobe Porosimeter and the Oilwell Research Porosimeter. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1950.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account