d) Aker flotation machines:

- Organization:
- Canadian Institute of Mining, Metallurgy and Petroleum
- Pages:
- 1
- File Size:
- 48 KB
- Publication Date:
- Jan 1, 1984
Abstract
"R. Tenbergen Is this flotation machine suitable in the flotation ofInco ball mill discharges where we have a coarse feed at 60% solids?Reply Experience has shown that there is not a significant increase in the wear life of these machines when handling coarse material (8 mesh) at 60% solids. A common practice in Europe is shut down on the week-ends.The material is allowed to settle and on start-up an injectic of air for 15 seconds is sufficient prior to start-up. At,mining we put our unit in the middle of a bank of 44 cells and in order to ensure severe sanding we shut the aker cell down while the remaining cells kept running. After 20-25 seconds of air the cell started without trouble.P. Mahant Is there a build-up inside the impellor shaft housing? Falconbrige Ltd.Reply There is no sand build-up but rather a scale build-up which due to a flexing action frees itself periodically. Part of the design of the machine permits a water injection into the shaft housing to free any build-up. This is done in Europe during the week-end shut down."
Citation
APA:
(1984) d) Aker flotation machines:MLA: d) Aker flotation machines:. Canadian Institute of Mining, Metallurgy and Petroleum, 1984.