Abstract

The method for design of primary roof support for the large todoidal cavern constructed to house the Sydney Opera House parking station is presented. The cavern was constructed with 5 m of rock cover beneath Sydney's Royal Botanic Gardens. Design of rock reinfonnent using a combination of fully grouted rock dowels and Macalloy bars was based on control of horizontal shear movement along bedding features in the roof. A combination of linear arch type analyses and non-linear jointed finite element analyses were used in the design study together with an analysis of the shear resistance offered by fully grouted bolts under shear deformation.