Determining Operating Points Of Multiple-Fan Ventilation Systems By Tracing An Augmented-System Solution Curve

- Organization:
- Society for Mining, Metallurgy & Exploration
- Pages:
- 6
- File Size:
- 386 KB
- Publication Date:
- Jan 1, 1994
Abstract
Based on systematic definitions of a generalized multiple fan ventilation system, the concepts of an augmented system, its solution curve and the operating points of the original system are introduced. The Quasi-Newton algorithm is applied in combination with the switching-parameter method to ensure a continuous search along an augmented-system solution curve and identify all the possible system operating points on it. Two example networks are analyzed to demonstrate those concepts and the application of the algorithm for identifying operating points of multiple fan ventilation systems.
Citation
APA:
(1994) Determining Operating Points Of Multiple-Fan Ventilation Systems By Tracing An Augmented-System Solution CurveMLA: Determining Operating Points Of Multiple-Fan Ventilation Systems By Tracing An Augmented-System Solution Curve. Society for Mining, Metallurgy & Exploration, 1994.