Dynamic Monitoring And Analysis Of Pile Foundation Installations ? Introduction

Deep Foundations Institute
Patrick J. Hannigan
Organization:
Deep Foundations Institute
Pages:
72
File Size:
4773 KB
Publication Date:
Jan 1, 1990

Abstract

The pile foundation designer typically performs a subsurface exploration program and static pile capacity calculations before selecting a pile foundation type, length, and capacity. During construction, a pile installation criterion must be established to meet these design requirements. This installation criterion usually consists of a minimum penetration resistance or blow count to confirm pile capacity and may also include a minimum embedment requirement. This text will focus on use of wave equation analysis and dynamic measurements to meet design requirements. BEFORE THE WAVE EQUATION Since the mid-1800s, over 450 dynamic formulas for pile driving control have proliferated. In their simplest form, these formulas relate hammer energy to the work of soil resistance, or simply: W ? h = R ? s (1) Where W = ram weight h = ram drop height or stroke R = pile capacity s = pile penetration per blow
Citation

APA: Patrick J. Hannigan  (1990)  Dynamic Monitoring And Analysis Of Pile Foundation Installations ? Introduction

MLA: Patrick J. Hannigan Dynamic Monitoring And Analysis Of Pile Foundation Installations ? Introduction. Deep Foundations Institute, 1990.