Evaluation Of Dust Exposures Associated With Mist Drilling Technology For Roof Bolters

Society for Mining, Metallurgy & Exploration
T. W. Beck
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
5
File Size:
4256 KB
Publication Date:
Jan 1, 2008

Abstract

Overexposure to respirable dust remains a widespread health hazard to roof bolter occupations in underground coal mines. Recently implemented mist drilling technology was evaluated for its effectiveness in controlling respirable dust exposures for roof bolting personnel. This work presents the findings from NIOSH field and laboratory studies comparing respirable dust levels on mist drilling roof bolter machines to dust levels measured on machines using a conventional vacuum drilling system. Gravimetric and instantaneous respirable dust samples were collected for multiple drilling cycles. These dust measurements were used to assess the potential dust control capabilities relative to conventional drilling. Controlled laboratory tests found 0.3 mg/m3 more respirable dust with mist drilling than with the conventional vacuum method. A separate field investigation of the two techniques observed higher dust levels around the mist bolting machine.
Citation

APA: T. W. Beck  (2008)  Evaluation Of Dust Exposures Associated With Mist Drilling Technology For Roof Bolters

MLA: T. W. Beck Evaluation Of Dust Exposures Associated With Mist Drilling Technology For Roof Bolters. Society for Mining, Metallurgy & Exploration, 2008.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account