Evaluation Of Inlet Ductwork Pressure Losses For Main Mine Fans

Society for Mining, Metallurgy & Exploration
Richard Druesedow Richard Ray
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
6
File Size:
252 KB
Publication Date:
Jan 1, 1993

Abstract

Tests at the VP-5 "C" shaft fan installation of Island Creek Coal's Virginia Pocahontas Mines were performed to determine pressure drop due to the design of the shaft collar and ductwork leading to the fan. Data from the test locations in the shaft, duct and fan indicate significant pressure losses in the system as well as significant turbulence in the flow. Data taken with a 3-D probe in the fan annulus confirmed the importance of using this type of instrument in turbulent flow applications. This data will be later supplemented with data taken after addition of turning vanes in the 45° turn adjacent to the fan inlet.
Citation

APA: Richard Druesedow Richard Ray  (1993)  Evaluation Of Inlet Ductwork Pressure Losses For Main Mine Fans

MLA: Richard Druesedow Richard Ray Evaluation Of Inlet Ductwork Pressure Losses For Main Mine Fans. Society for Mining, Metallurgy & Exploration, 1993.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account