Flotation Rate Versus Particle Size And Agitation Levels In The Air Dispersion And Collection Zones For Chalcopyrite/Silica Mixtures

- Organization:
- Society for Mining, Metallurgy & Exploration
- Pages:
- 6
- File Size:
- 278 KB
- Publication Date:
- Jan 1, 1990
Abstract
Using an agitated column 203 mm (8") diameter by 1829 mm (72") tall with independent agitation units for the gas dispersion zone and the collection zones, respectively, permitted the independent evaluation of the attachment and the detachment mechanisms for the chalcopyrite/ silica system. Three particle size fractions were used in this study, i.e. coarse (+75 µ m), intermediate (-75 µ m + 10 µ m) and fines (-10 µ m). The optimum selection of the two agitation zones for the three particle size fractions were determined as a function of grade, recovery, residence time and air superficial gas velocity.
Citation
APA:
(1990) Flotation Rate Versus Particle Size And Agitation Levels In The Air Dispersion And Collection Zones For Chalcopyrite/Silica MixturesMLA: Flotation Rate Versus Particle Size And Agitation Levels In The Air Dispersion And Collection Zones For Chalcopyrite/Silica Mixtures. Society for Mining, Metallurgy & Exploration, 1990.