Several purifying techniques have been developed for controlling the impurity levels in the copper electrolyte at Niihama Copper Refinery. These have been carried out as follows; i ) the study of the reaction in liberation made it possible to raise the current efficiency for arsenic removal by more than 50% and to decrease generation of arsine sharply. By applying this method, a good performance was attained at commercial operation. li) the antimony in the electrolyte can be successfully removed by contacting it with activated carbon. This procedure is applicable particularly when there is a large amount of antimony in the copper anode. lli) for the nickel sulphate recovery from the electrolyte, an electric evaporating system was developed. The characteristics of this process are, capability of continuous operation with less manpower, the high recovery ratio of nickel sulphate (more than 85% as nickel) and no black acid formation in the treated solution.