Abstract
In aging tunnels, wall and roof deterioration can eventually result in defects that must be detected and repaired to maintain safe structural conditions. In investigating tunnel defect conditions, a specialized FM radar system was developed with a programmable VHF and UHF operating sweep range for optimizing the penetration and measurement capabilities. The new FM radar technology was tested in two aging brick-lined tunnels in New York City. Test results showed that FM radar signals could penetrate eight courses of water-saturated brick and that the original steel liner outside the tunnel walls was intact.