Institute of Metals Division - Metallographic Observations of the Deformation of High-Purity Magnesium in Creep at 500°F

The American Institute of Mining, Metallurgical, and Petroleum Engineers
A. R. Chaudhuri N. J. Grant J. T. Norton
Organization:
The American Institute of Mining, Metallurgical, and Petroleum Engineers
Pages:
5
File Size:
64 KB
Publication Date:
Jan 1, 1954

Abstract

MOST of the recent work to establish the mech-anism of creep in metals at high temperatures has utilized aluminum as the experimental material. It was thought desirable to initiate an investigation of a hexagonal close-packed metal, because of the relatively simple slip system, and compare the observed deformation characteristics with those that have been observed for the face-centerd cubic metals. High-purity magnesium was chosen for this purpose, first, because its strength and other mechanical properties are similar to those of aluminum in the same temperature range, and second, because the existing equipment was ideally suited to observe magnesium during creep. It is proposed in this paper to present a pictorial and qualitative account of the changes that high-purity magnesium undergoes during creep at 500°F. The characteristics of deformation of aluminum described below have been observed by various workers and accounts of these may be obtained from the papers of Chang and Grant.'- These characteristics are: slip, subgrain formation, grain boundary sliding and migration, fold formation, deformation bands, and kink bands. It is well known that in a flat magnesium specimen, slip on the basal plane (0001) in the [1120] direction results in the formation of straight bands on the surface of the specimen. Schmid and co-workers' have shown that this system is operative in the temperature range of -185" to 300°C (-300° to 572°F). They have also shown that a second system, slip on the pyramidal planes {1071} or {1012} in the [1120] direction, is operative at temperatures higher than 225°C (437°F). Between 225° and 300°C (437" to 572°F), therefore, deformation by both these systems is expected. Bakarian and Mathewson5 confirmed the occurrence of pyramidal slip on the {1011} plane and found that it resulted in irregular markings on the surfaces of their specimens. Burke and Hibbard6 obtained evidence of pyramidal slip in single crystals of magnesium deformed at room temperature. Bakarian and Mathewson5 suggested that the irregular appearance of these bands was due to slip on both of the pyramidal planes occurring simultaneously but in the same direction, the close angular relationship between the planes making this process possible. Furthermore, since neither of these planes is close enough to the basal plane, slip on the latter does not exhibit the irregular appearance of slip bands resulting from pyramidal slip. Experimental Procedure High-purity magnesium, supplied by the Dow Chemical Co., was used in these experiments. The analysis was as follows: Al, 0.0002 pct; Mn, 0.0018; Fe, 0.0024; Cu, 0.0002; Sn, 0.001; Ca, 0.01; Ni, 0.0003; Zn, 0.01; Pb, 0.0005; Si, 0.001; and Mg, 99.972. The magnesium was supplied in the form of 1/2 in. diam rods. The specimens had an overall length of 21/4 in., the round ends being threaded to fit the specimen holders. The previously round 3/16 in. diam gage section of the specimen had two parallel flats machined on opposite sides for microscopic observation, yielding a test zone having the dimensions of lx3/16x7/64 in. The specimens were electrolytically polished (without prior mechanical polishing of the machined flats), in a solution composed of 375 ml of ortho-phosphoric acid and 625 ml of ethyl alcohol.' The cathode was a stainless steel sheet bent so that the specimen was completely surrounded. The voltage for successful polishing was 1.5 v at 100 to 300 milli-amp current. Electropolishing for about 45 min sufficed to obtain a good metallographic surface on the specimens after they had been machined. The creep tests were performed under constant load, and two types of equipment were used. In the first, designed by Servi and Grant,V he specimens were beam-loaded, and a furnace could be lowered to surround the specimen. As the microstructural changes could not be observed during the course of the test, the tests had to be interrupted periodically by removing the specimen for microscopic examination. The second unit was a high temperature microscopy furnace designed by Chang and Grant.' The furnace was fitted with an optically flat quartz window having area dimensions 1.25x0.5 in., so that the whole test portion could be viewed through it at magnifications up to x240. The metallurgical microscope had three mutually perpendicular axes of motion, and, in addition, it was possible to measure angular displacements by rotation of the eyepiece. It was thus possible to make precise observations of the specimen during creep, and micrographs could be taken by attaching a camera to the eyepiece of the microscope. The average grain size of the specimens that were tested was about 1 to 3 mm. This grain size could
Citation

APA: A. R. Chaudhuri N. J. Grant J. T. Norton  (1954)  Institute of Metals Division - Metallographic Observations of the Deformation of High-Purity Magnesium in Creep at 500°F

MLA: A. R. Chaudhuri N. J. Grant J. T. Norton Institute of Metals Division - Metallographic Observations of the Deformation of High-Purity Magnesium in Creep at 500°F. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1954.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account