In late October 1996, an acid plant at a major U.S. copper smelter was faced with unexpected and rapidly increasing pressure drop across the gas cooling tower in the acid plant, indicating a build-up on the packing. This threatened to halt operations if not resolved. Earlier that month, a smaller vessel in the acid plant was found to be completely plugged with lead sulfate. It was feared that a similar fate awaited the gas cooling tower unless the scale build-up was stopped. Although lead sulfate is present in most copper smelter acid plants, this accumulation was unusually severe. An investigation was launched to find the source of the lead, determine how lead is transported to the gas cooling tower, recommend operating practices to prevent such severe scaling, and seek ways to recycle the lead value in the scale covered polypropylene packing. Late in the investigation it was learned that the lead originated from an improperly executed recycling program.