Load In A Drilled Foundation. Where Did It Go And When Did It Get There?

- Organization:
- Deep Foundations Institute
- Pages:
- 8
- File Size:
- 1647 KB
- Publication Date:
- Jan 1, 2004
Abstract
Three drilled foundations for an elevated water-tank were instrumented, tested and monitored during construction and the first two years in service. One shaft was load tested by the Osterberg method. A void was detected in one shaft by cross-hole sonic logging, pulse-echo logging and concrete coring. The void was instrumented, hydrostatically tested and pressure grouted. The shaft was ?abandoned? and replaced by two smaller shafts with a straddle beam cap. One of the replacement shafts and the cap were instrumented. The strain that appeared in the abandoned shaft, the replacement shaft and the cap were monitored during the remainder of the construction, through the commissioning test and the first two years of service. The results demonstrate the precision and sensitivity of the vibrating wire strain gage.
Citation
APA:
(2004) Load In A Drilled Foundation. Where Did It Go And When Did It Get There?MLA: Load In A Drilled Foundation. Where Did It Go And When Did It Get There?. Deep Foundations Institute, 2004.