Matching Fan Performance And Air Resistance In A Drift With A Leaky Brattice

Society for Mining, Metallurgy & Exploration
J. T. Ryan Griffin. Wayne H.
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
4
File Size:
198 KB
Publication Date:
Jan 1, 1993

Abstract

This paper shows that if a drift has a brattice which is sufficiently leaky, changes in the operating point of the fan depend solely on the volumetric efficiency within the drift. Under this high leakage condition, an increase in the length of the drift causes very little shift in the fan operating point. For less leaky brattices, the operating point depends on both the fan characteristic curve and the volumetric efficiency. It is shown that for the fan curve and drift parameters used in this paper the fan operating point in a drift with a volumetric efficiency of 50% is essentially the same as a drift which has a zero efficiency. In this region of efficiency, an increase of 300% in the length of the drift causes only a 3% increase in fan operating pressure.
Citation

APA: J. T. Ryan Griffin. Wayne H.  (1993)  Matching Fan Performance And Air Resistance In A Drift With A Leaky Brattice

MLA: J. T. Ryan Griffin. Wayne H. Matching Fan Performance And Air Resistance In A Drift With A Leaky Brattice. Society for Mining, Metallurgy & Exploration, 1993.