Abstract
Mercury is introduced into EZ's electroly tic zinc/sulphuric acid plant complex at Risdon, Tasmania, in zinc sulphide concentrate. Mercury is volatilised during the roasting operation and then distributed in the sulphuric acid plant effluents and product acid. Following an investigation of the factors determining the mercury distribution, a plan was formulated to-provide an environmentally accep- table degree of mercury containment at Risdon. This paper discusses details of the various control measures investigated and out- lines the reasons for selecting the particular procedures finally adopted for the Risdon plant.
Citation
APA: