Modifications to improve sediment pond performance

- Organization:
- Society for Mining, Metallurgy & Exploration
- Pages:
- 5
- File Size:
- 246 KB
- Publication Date:
- Jan 1, 1987
Abstract
Three sedimentation ponds had their performance evaluated before and after installation of modifications. Each pond had a floating baffle installed, two had siphon outlets, and one had a floating outlet device. Baffles inhibited short circuiting, and the outlet devices retarded flow following a rainfall event and drained the pond, creating a large storage volume to maximize detention time. Total suspended solids and settleable solids tests were measured on samples of influent and effluent to evaluate pond performance. Particle size analyses were conducted on samples containing measurable amounts of solids. Performance improved in each pond, with baffles providing the major improvement.
Citation
APA:
(1987) Modifications to improve sediment pond performanceMLA: Modifications to improve sediment pond performance. Society for Mining, Metallurgy & Exploration, 1987.