Monitoring of the Sydney Opera House Underground Parking Station

- Organization:
- The Australasian Institute of Mining and Metallurgy
- Pages:
- 14
- File Size:
- 1243 KB
- Publication Date:
- Jan 1, 1993
Abstract
The excavation for the Sydney Opera House Parking Station comprises a large donut shaped underground cavern with a central sandstone pillar. The maximum effective roof span is about 19 m and the rock cover is between 7 m and 8 m. Permanent support for the roof and the various services tunnels consists of a combination of tensioned anchors, and untensioned dowels, and mesh with shortcrete and fibrecrete as the final lining. Steel sets were installed at main intersections.Fundamental to the design philosophy for excavation of these spans at such shallow rock cover was the use of monitoring to check on the adequacy of the installed support. Prior to excavation, extensometers, inclinometers, piezometers and surface settlement survey stations were installed. Underground survey stations, anchor load cells and shotcrete pressure cells were installed as excavation proceeded. Excavation commenced at the crown using an initial heading and three widening stages. Geological mapping during excavation confirmed borehole expectations, namely sandstone beds 1 to 4 m thick interbedded with thin shale units. Bedding plane contacts varied over short distances from tight partings to thick brecciated seams. Jointing was subvertical and joints tended to be bed-limited.
Citation
APA: