OFR-106-77 Time Domain Reflectometry Microcomputer

The National Institute for Occupational Safety and Health (NIOSH)
Roger A. Dworak
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
115
File Size:
33376 KB
Publication Date:
Jan 1, 1977

Abstract

This report describes in detail the work done on the development of the Time Domain Reflectometry Microcomputer (TDRM). Modifications to the FMC-Model 302A Cable Fault Locator is described in Appendix D. The TDRM unit uses an 8080 microcomputer to accurately locate major faults in low capacitance cables to within ± 1 foot when properly calibrated. Major faults in high capacitance cables are usually located within ± 5 feet. The upper limits of fault detection are <1 kilohm shunt fault and >7 ohm series fault. In practice fault detection limits are reduced to <300 ohms shunt fault and >30 ohms series fault because of discontinuities caused by cable repair.