OFR-28-78 Analysis Of Toxic Fumes Generated During Shot Firing

- Organization:
- The National Institute for Occupational Safety and Health (NIOSH)
- Pages:
- 37
- File Size:
- 9387 KB
- Publication Date:
- Jan 1, 1977
Abstract
Toxic fumes generated during shot firing under actual mining conditions were measured. Eight shots with Gelodyn-2X and seven shots with Tovex-100 4VT were monitored. Average CO values for Gelodyn-2X and Tovex-100 4VT were 0.20 ft3/lb and 0.09 ft3/lb, respectively. Average N0x values for Gelodyn-2X and Tovex-100 4VT were 0.049 ft3/lb and 0.026 ft3/lb, respectively. The results obtained with these in-mine tests will be used by the U.S. Bureau of Mines in the development of a large chamber method of measuring fumes from shotfiring of explosives.
Citation
APA: