OFR-64-82 Taconite Crusher Noise Reduction-Study Of Acoustical Enclosure For Symons 7 Foot, Standard Head, Extra-Heavy Duty Cone Crusher

The National Institute for Occupational Safety and Health (NIOSH)
James A. Morgan
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
40
File Size:
6551 KB
Publication Date:
Jan 1, 1980

Abstract

FIELD MEASUREMENTS OF NOISE WERE MADE ON THE PERIPHERY OF ENCLOSURES DESIGNED, MANUFACTURED AND INSTALLED BY INDUSTRIAL ACOUSTICS COMPANY, INC. ON THE SECONDARY TACONITE CRUSHER AT THE JACKSON COUNTY IRON COMPANY PLANT IN BLACK RIVER FALLS, WISCONSIN. NOISE REDUCTION ACHIEVED BY THE ENCLOSURES WAS SUFPICIENT TO PERMIT REDUCTION OF CRUSHER ROOM NOISE TO 90 DBA, PROVIDED THAT OTHER SOURCES ARE APPROPRIATELY TREATED AND ACOUSTICAL ABSORPTION IS PROVIDED IN THE CRUSHER ROOM. SECONDARY CRUSHER NOISE WAS REDUCED 10 TO 15 DBA BY THE ENCLOSURES.
Citation

APA: James A. Morgan  (1980)  OFR-64-82 Taconite Crusher Noise Reduction-Study Of Acoustical Enclosure For Symons 7 Foot, Standard Head, Extra-Heavy Duty Cone Crusher

MLA: James A. Morgan OFR-64-82 Taconite Crusher Noise Reduction-Study Of Acoustical Enclosure For Symons 7 Foot, Standard Head, Extra-Heavy Duty Cone Crusher. The National Institute for Occupational Safety and Health (NIOSH), 1980.