Part VII – July 1969 – Papers - Dynamic X-Ray Diffraction Study of the Deformation of Aluminum Crystals

- Organization:
- The American Institute of Mining, Metallurgical, and Petroleum Engineers
- Pages:
- 5
- File Size:
- 319 KB
- Publication Date:
- Jan 1, 1970
Abstract
Several experiments have been performed in order to illustrate the application of a recently developed X-ray image intensifier system to metallurgical investigations. In the present work the system has been used to study the instantaneous alterations in Laue transmission X-ray diffraction patterns during tensile deformation of aluminum single crystals. Expem'mental results are presented which demonstrate the capability of the system for crystal orientation, for following orientation changes due to lattice rotation during tensile deformation, and for showing changes in the homogeneity of the lattice planes along the specimen length as a function of strain rate. RECENTLY, a new X-ray system has been developed which incorporates a cascaded image intensifier and permits direct viewing and recording of X-ray diffraction patterns produced on a fluorescent screen.1"3 In the present work the results of several experiments are presented which demonstrate the usefulness of this system for metallurgical applications. EXPERIMENTAL PROCEDURE A schematic diagram of the experimental arrangement is shown in Fig. 1. In this system a Machlett AEG-50-S tungsten target X-ray tube, normally operated at 50 kv and 40 ma, serves as the X-ray source. The X-ray tube is placed in direct contact with a 10-in.-long collimator, which transforms the X-ray beam from one with a circular cross section to one with a rectangular cross section 3 in. high and 1/6in. wide. By blocking off all but a small portion of the rectangular slit, it is possible to work with the more conventional "pinhole" collimated X-ray beam commonly used for obtaining Laue diffraction patterns. In the present work the test specimens were 99.99+ pct aluminum single crystal wires & in. in diam and 3 in. long. For the deformation tests the wire crystals were mounted in a special set of grips in a table model Instron machine so that diffraction patterns could be recorded during specimen deformation. For the orientation tests the wire crystals were mounted in a rotating goniometer so that diffraction patterns could be recorded during specimen rotation. At a distance of 3 cm from the specimen axis, a 6 in. diam DuPont CB-2 fluorescent screen is positioned to transform the X-ray image to a visible one. A Super Farron f/0.87 72 mm coupling lens, corrected for 4 to 1 demagnification, transmits the visible image to the image tube. The image intensifier used is a three-stage magnetically focused RCA type C70021A with an S-20 input photocathode and a P-20 output phosphor. The tube has unity magnification and useful input and output screen diameters of 1.5 in. The image on the output phosphor is of sufficient intensity to be viewed directly, to be recorded cine-matographically, or to be displayed by vidicon pick-up on a television monitor. The recording device most commonly used is a 16 mm Bolex motion picture camera fitted with a Canon f/0.95, 50 mm lens. The overall gain of the system is 16,000 for direct viewing and 2240 for recording on 16 mm movie film. The resolution of the system is limited to 1 line pair per mm which is approximately that of the fluorescent screen. This system has been used for cine recording of transmission Laue X-ray diffraction patterns with exposure times as short as 1/220 sec and for vidicon television pick-up and display at a scan time of 1/30 sec. Quantitative information may be obtained from each frame of the movie film, by either stopping the vertical slit down to a point source in order to obtain a conventional Laue photograph or else by retaining the linear beam and introducing fiducial marks as described in a previous paper.4 In either case, each frame may be enlarged to appropriate size for analysis by either using a photographic enlarger and making prints of the desired frames, or, more conveniently, by using a microfilm reader. EXPERIMENTAL RESULTS The first series of photographs which are presented in Fig. 2 serves to demonstrate the usefulness of the system for crystallographic orientation determination. This series of prints, made from enlargements of a 16 mm movie film, shows the dynamic Laue transmission patterns produced by an aluminum single crystal wire which was rotating about the wire axis when the patterns were recorded. The movie films were taken at 16 frames per sec and the crystal was rotated at a rate of 15 rpm.
Citation
APA:
(1970) Part VII – July 1969 – Papers - Dynamic X-Ray Diffraction Study of the Deformation of Aluminum CrystalsMLA: Part VII – July 1969 – Papers - Dynamic X-Ray Diffraction Study of the Deformation of Aluminum Crystals. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1970.