Abstract
The mechanical properties of 300-series stainless steels were investigated in both high-pressure hydrogen and helium environments at ambient temperatures. An auslenitic steel which is unstable with respect to formation of strain-induced a (bee) and € (hcp) mar-tensile is embrittled when plastically strained in a hydrogen environment. A stable austenitic steel is not embriltled when tested under the same conditions. The presence of hydrogen causes embrittlement at the mar-lensitic structure and a definite change in the general fracture mode from a ductile to a quasicleavage type. The embrittled martensitic facets are surrounded by a more ductile type fracture which suggests that the presence of hydrogen initiates microcracks at the martensitic structure. If a steel is unstable with respecl to fortnation of strain induced martensile, plastic deformation in a hydrogen environment will produce rapid embrittlement of a notched specimen in comparison to an unnotched one. FERRITIC and martensitic steels can be embrittled by hydrogen that has been introduced into the alloys, either by thermal or cathodic charging prior to testing.1-5 However, conflicting reports exist as to whether austenitic steels that are stable or unstable with respect to formation of strain-induced martensite can be embrittled by hydrogen.8-12 A recent investigation has shown that cathodically-charged thin foils of a stable austenitic steel can be embrittled.13 An earlier investigation of a thermally charged 18-10 stainless steel revealed a significant decrease in the ductility only at the lowest test temperature of -78°C, although strain-induced bee martensite was shown to be present in one specimen tested at ambient temperatures.' When martensitic steels are tested in a hydrogen atmosphere, they are embrittled.'4-'7 It has been observed in this Laboratory that 304L steel, which is unstable with respect to formation of strain induced martensite, forms surface cracks when plastically strained in a high-pressure hydrogen environment. Work in progress elsewhere concurrent with this investigation has also established that 304L is embrittled when tested in a high-pressure hydrogen atmosphere." The objective of this investigation was to study the effect of a high-pressure hydrogen environment on the tensile properties of a stainless steel that contained strain-induced martensite (304L) and one that did not (310). EXPERIMENTAL TECHNIQUES Notched and unnotched cylindrical specimens were machined from 304L* and 310 rods that were heat- treated at 1000°C in argon for 1 hr followed by a water quench. The chemical analyses of these steels are given in Table I. The unnotched specimens had a reduced section diameter of 0.184 & 0.001 in., a gage length of 0.7 in., and were threaded with a 0.5-in.-diam. thread on each end. The notched specimens had a reduced section diameter of 0.260 * 0.001 in. and a 0.75-in. gage length, with a 30 pct 60 deg v-notch at the center. The notch had a maximum root radius of 0.002 in. The tensile bars were fractured in a hydrogen or helium atmosphere of 104 psi at ambient temperatures. The system used for mechanically testing the specimens is to be described in detail elsewhere.19 Several specimens of each type were tested in air using an Instron testing machine. The same yield strength and ultimate tensile strength were obtained in 104 psi helium with the above system as with the conventional testing machine. Magnetic analysis was employed to determine that there was a (bee) martensite in plastically deformed 304L and that it was not present in plastically deformed 310. The magnetic technique depended on allowing the material being studied to serve as the core between a primary and secondary coil. Thus, any change in the amount of magnetic material present between the annealed and plastically deformed steels will be indicated by corresponding changes in the induced voltage in the secondary circuit." The ratio of the output signal of a nonmagnetic stainless steel to a completely magnetic maraging steel was 2000 to I. Several unnotched 304L bars tested in hydrogen were analyzed for hydrogen by vacuum fusion analysis. There was an increase in the hydrogen content to approximately 2 ppm for the specimens tested in hydrogen, as compared to less than 1 ppm for the as-received material. Several thin sections cut from notched areas of 304L specimens tested in hydrogen and containing the fracture surface contained approximately 1.5 ppm H. The accuracy of these determinations was estimated to be ± 50 pct.
Citation
APA:
(1969) Part X – October 1968 - Papers - Hydrogen Ernbrittlement of Stainless SteelMLA: Part X – October 1968 - Papers - Hydrogen Ernbrittlement of Stainless Steel. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1969.