Performance of On-Stream Analyzers At Outokumpu Concentrators, Finland

- Organization:
- Canadian Institute of Mining, Metallurgy and Petroleum
- Pages:
- 11
- File Size:
- 7912 KB
- Publication Date:
- Jan 1, 1973
Abstract
"The Courier 300 on-stream analysis system manufactured by Outokumpu has now been in operation at five of the company's concentration plants long enough to give a reliable basis for closer examination of the benefits achieved in control of these processes. The first system was installed at the Pyhiisalmi mine at the end of 1967. Since November 1970, two analyzers have been in operation at Pyhiisalmi feeding the assay data to a process computer which controls the whole plant and does the optimization of the process. In October 1970 the Courier 300 analysis system was installed at S. T. O. LESKINEN J. KOSKINEN the Keretti concentrator of the Outokumpu mine, followed soon by installations at the Vihanti Mine in May 1971, at the new Vuonos mine in November J 971 and at t he Kotalahti mine in December 1971. Since installation of the Courier analysis systems, considerable improvements have been achieved in the control and the economy of the plants. Immediate knowledge of the changes in the process and the possibility for rapid action has resulted in evener production and higher capacity and recovery. The recovery has been increased most significantly at the Vihanti concentrator, which operates on a complex ore. Consumption of chemicals has been reduced at all concentrators. Due to the fact that process control and partly also bilance analysis are not achieved by conventional methods any more, it has been possible to reduce the personnel of the laboratories drastically. Two of the plants, viz. the Pyhiisalmi and the Vuonos concentrators, are computercontrolled. The Vuonos concentrator started operation in January 1972 under computer control from the very beginning. The Pyhiisalmi concentrator has been computer-controlled since 1970. The Courier 300 analysis system was described in detail at the AIME Centennial Annual Meeting (1971). In this paper, less attention is paid to the analysis system. Only the sampling system of the Courier 300 is described in more detail. In the development of sampling equipment, effective use has been made of the company's wide knowledge of the problems involved and the test field offered by its concentrators. The sampling equipment includes secondary samplers and six basically different types of primary samplers, with which most sampling situations can be managed."
Citation
APA:
(1973) Performance of On-Stream Analyzers At Outokumpu Concentrators, FinlandMLA: Performance of On-Stream Analyzers At Outokumpu Concentrators, Finland. Canadian Institute of Mining, Metallurgy and Petroleum, 1973.