Plant Trial of an Under-belt Capacitance and Gamma-Ray Backscatter Gauge for on-Belt Determination of Moisture in Coal

- Organization:
- The Australasian Institute of Mining and Metallurgy
- Pages:
- 8
- File Size:
- 890 KB
- Publication Date:
- Jan 1, 1989
Abstract
A non-contacting under-belt capacitance and gamma-ray backscatter technique has been developed for the on-line measurement of moisture in coal. In this technique, moisture was correlated with radio frequency susceptance and conductance determined using an under-belt capacitance sensor in which a fringing electric field Interrogates a layer of coal on the conveyor belt directly above the sensor. To compensate for variations in the density and thickness of the coal layer, an under-belt gamma-ray backscatter gauge was used to measure an equivalent volume of coal.A plant trial of the technique was conducted at Stockton Borehole Colliery, SW Australia, where the gauges were installed on the coking coal product conveyor. Product moistures, in the range 7 - 14%, were determined with r.m.s errors of 0.50 and 0.25 wt% using on-belt and static off-belt gauges, respectively. The difference in the on-belt and off-belt gauge measurement accuracy was attributed to sampling errors in the calibration of the onbelt gauge.
Citation
APA: (1989) Plant Trial of an Under-belt Capacitance and Gamma-Ray Backscatter Gauge for on-Belt Determination of Moisture in Coal
MLA: Plant Trial of an Under-belt Capacitance and Gamma-Ray Backscatter Gauge for on-Belt Determination of Moisture in Coal. The Australasian Institute of Mining and Metallurgy, 1989.