Practical Application Of PSM At Golden Sunlight Mines

Society for Mining, Metallurgy & Exploration
G. B. Amicucci
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
6
File Size:
297 KB
Publication Date:
Jan 1, 1991

Abstract

A Denver Autometrics Particle Size Monitor, PSM-400, was installed at Golden Sunlight Mines, Inc. in October 1988. The PSM-400 measures the grind product's particle size and percent solids. The particle size is used to control grind size by automatically adjusting mill feed rate. The PSM's continuous response to ore changes has improved grind product uniformity and mill throughput. Metallurgical testing has shown the PSM's accuracy to be +/-1 % + 150 µm (100 mesh).
Citation

APA: G. B. Amicucci  (1991)  Practical Application Of PSM At Golden Sunlight Mines

MLA: G. B. Amicucci Practical Application Of PSM At Golden Sunlight Mines. Society for Mining, Metallurgy & Exploration, 1991.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account