RI 4067 Apparatus for Determining the Reactivity of Calcium Carbide and Acetylene-Water Vapor Mixtures

The National Institute for Occupational Safety and Health (NIOSH)
G. W. Jones G. S. Scott R. E. Kennedy I. Spolan
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
46
File Size:
6561 KB
Publication Date:
Apr 1, 1947

Abstract

In studies made by the United States Bureau of Mines to determine the causes of explosions in medium-pressure acetylene generators , it was shown that when these are operated at elevated temperatures the acetylene liberated in an acetylene generator carries enough water vapor to heat certain types of carbides to a high temperature , when the acetylene- water vapor mixtures are passed through the carbide . This report contains results of further work carried out to develop an apparatus to show the heating effects or reactivity of various types of carbides in contact with acetylene - water vapor mixtures .
Citation

APA: G. W. Jones G. S. Scott R. E. Kennedy I. Spolan  (1947)  RI 4067 Apparatus for Determining the Reactivity of Calcium Carbide and Acetylene-Water Vapor Mixtures

MLA: G. W. Jones G. S. Scott R. E. Kennedy I. Spolan RI 4067 Apparatus for Determining the Reactivity of Calcium Carbide and Acetylene-Water Vapor Mixtures. The National Institute for Occupational Safety and Health (NIOSH), 1947.