Abstract
The data collected during this investigation indicate that the chromiumgadolinium
system has extensive liquid immiscibility and one eutectic point .
Liquid immiscibility occurred at temperatures above the monotectic isotherm ,
1,830 ° C , which extended from less than 0.25 to about 85 weight - percent
gadolinium . The eutectic was at 96 percent gadolinium and 1,170 ° C. Gadolinium
and chromium were the only phases in this system . There was a solid
solubility of less than 0.25 percent gadolinium in chromium at 1,730 ° C and
less than 0.10 percent chromium in gadolinium at 1,160 ° C.
The alloys were prepared by nonconsumable - electrode arc - melting , and the
alloy system was investigated by heat treatment , metallography , thermal analysis
, and X- ray diffraction . All the melting , heat treatments , and thermal
analyses were conducted in a vacuum or in helium because of the reactivity of
chromium and gadolinium with the components present in the atmosphere at
elevated temperatures .
Citation