RI 7625 Flame Spread Evaluation Of Ventilation Cloth

- Organization:
- The National Institute for Occupational Safety and Health (NIOSH)
- Pages:
- 12
- File Size:
- 3333 KB
- Publication Date:
- Jan 1, 1972
Abstract
Comparative data from ASTM method of test E-162 and large-scale trials in the Experimental Mine show that the flame-spread quality of brattice cloth and other ventilation control materials can effectively be evaluated by either method. Materials having a flame spread index of 25 or less, as determined by the simpler and more economical laboratory test ASTM E-162, do not present a serious fire hazard when used in coal mines.
Citation
APA:
(1972) RI 7625 Flame Spread Evaluation Of Ventilation ClothMLA: RI 7625 Flame Spread Evaluation Of Ventilation Cloth. The National Institute for Occupational Safety and Health (NIOSH), 1972.