Abstract
Eight brands (three samples of each kind) of commercially available audio-dosimeters were performance-tested. Each unit was placed in an anechoic chamber and subjected to various acoustic signals to measure its A-weighting response and overall integration accuracy. All units met the A-weighting tolerance for type II sould level meters, and six brands were within the Bureau I s overall accuracy requirements of ±2 dbA referred to input.
Citation
APA:
(1974) RI 7876 Noise Dosimeter PerformanceMLA: RI 7876 Noise Dosimeter Performance. The National Institute for Occupational Safety and Health (NIOSH), 1974.