Abstract
The U. S. Bureau of Mines performed experiments to determine if the primary gas toxicities evolved during the early (~300° C) and later (~400° C) combustion stages of chlorinated polyester-reinforced mine ventilation ducts could be predicted by a smoke particle characteristic, for the development of a test parameter. The experiments were conducted in an approximately 20-L furnace, at 14-min durations at set furnace temperatures of 2500 and 1,000° C, with an airflow through the furnace of 10 L/min. The variables studied, as a function of time, were the hydrogen chloride (HCI), carbon monoxide (CO), carbon dioxide (C02), and oxygen (02) concentrations, furnace temperatures, the sample mass weight loss, the average smoke particle diameter (dg and average number and concentration (no), and the product of the average smoke particle diameter and concentration (dgno). Results show that the inverse of the smoke particle diameter-concentration product [(l/dgn0)], correlates directly and significantly with the primary gas toxicities evolved during both early (HCI) and later (CO) stages of combustion.
Citation
APA:
(1989) RI 9284 - Primary Gas Toxicities and Smoke Particle Characteristics During Combustion of Mine Ventilation DuctsMLA: RI 9284 - Primary Gas Toxicities and Smoke Particle Characteristics During Combustion of Mine Ventilation Ducts. The National Institute for Occupational Safety and Health (NIOSH), 1989.