Satisfying Apparent Temperature Requirements in Mobile Refuge Alternatives Using Vapor Compression Refrigeration and Expendable Desiccant

Society for Mining, Metallurgy & Exploration
K. Deaton
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
3
File Size:
251 KB
Publication Date:
Jan 1, 2017

Abstract

"INTRODUCTION A packaged cooling system is being developed for refuge alternatives (RAs) that meets MSHA qualification guidelines for deployment in coal mines. This system will allow full occupancy ratings of deployed Refuge Alternatives (RAs) to be maintained by keeping the apparent temperature inside the RA from exceeding 95°F. Research investigations sponsored by NIOSH have shown that heat buildup caused by occupants in mobile RAs will result in apparent temperatures that exceed the 95°F limit established in 30 CFR 7.504. Figure 1 shows the temperature rise in an inflatable RA having an occupancy rating of 23 people at an 81°F mine air temperature. This plot shows the need for either heat mitigation or occupancy derating in warmer mines. The RAECS will be designed to provide enough heat mitigation to eliminate occupancy derating due to heat buildup over the 96 hour refuge period.This paper describes testing of a prototype cooling system that uses proven vapor compression technology powered by batteries to keep the RA interior below the 95° limit for a minimum of 96 hours. Testing of this prototype cooling system was conducted in December of 2015 and January of 2016 at the NIOSH test mine in Bruceton, PA. December testing was conducted at the prevailing mine ambient temperature – approximately 60°F. The January testing was done with the mine ambient temperature in the immediate vicinity of the RA artificially elevated to 85°F. Realistic heat gain from RA occupants was provided by human simulators developed by NIOSH. These simulators add sensible heat corresponding to human metabolic processes and latent heat generated by respiration and perspiration. Heat generated by CO2 scrubbers was also added. Results of cooling system performance using these simulated loads at the two ambient conditions are described. A comparison of the apparent temperature in the RA using two different control techniques is also presented. This work documents the ability of the cooling system to meet the established apparent temperature limit at the full occupancy rating of a six person RA. A new cooling system intended for use with existing RA deployments and having greater cooling capacity is currently in development and will be described."
Citation

APA: K. Deaton  (2017)  Satisfying Apparent Temperature Requirements in Mobile Refuge Alternatives Using Vapor Compression Refrigeration and Expendable Desiccant

MLA: K. Deaton Satisfying Apparent Temperature Requirements in Mobile Refuge Alternatives Using Vapor Compression Refrigeration and Expendable Desiccant. Society for Mining, Metallurgy & Exploration, 2017.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account