Technical Notes - An Fe-Cr-Mo-Ni Sigma Phase

The American Institute of Mining, Metallurgical, and Petroleum Engineers
A. G. Allten
Organization:
The American Institute of Mining, Metallurgical, and Petroleum Engineers
Pages:
2
File Size:
205 KB
Publication Date:
Jan 1, 1955

Abstract

EXAMINATION by metallographic and X-ray diffraction means of an austenitic steel containing 0.06 pct C, 1.26 pct Mn, 0.38 pct Si, 21.15 pct Ni, 18.72 pct Cr, 3.07 pet W, and 9.14 pet Mo indicated that a - phase, which had not been reported in the literature, existed in this steel. Both the s and car-bides of the M6 C type were present in the as-forged steel. The carbides dissolved completely in the aus-tenite at approximately 2200°F (1205°C). The s, however, was present at all temperatures up to the solidus temperature of the steel at approximately 2375°F (1300°C). Ferrite was not found in any condition of the steel. The faintness of some of the s lines in X-ray patterns obtained from samples of the steel made it desirable to isolate the s prior to verification of its entire pattern. It was found that the s phase could be separated from samples of the steel which had been water quenched from 2250°F (1230°C) by dis-
Citation

APA: A. G. Allten  (1955)  Technical Notes - An Fe-Cr-Mo-Ni Sigma Phase

MLA: A. G. Allten Technical Notes - An Fe-Cr-Mo-Ni Sigma Phase. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1955.