The Armor Pipe Roofing Method in Urban Tunnelling
 
    
    - Organization:
- The Australasian Institute of Mining and Metallurgy
- Pages:
- 10
- File Size:
- 868 KB
- Publication Date:
- Jan 1, 1976
Abstract
Construction and mining sites are often subject to unexpected flooding and extensive  delays may occur in locating and installing  emergency pumps. This particularly applies to  sites located in remote areas. A simple and effective pump, called an  air-lift pump, can be built from the equipment  available at the working site. The basic req- uirements are a compressed air supply, air hose  and conventional water pipes. The air-lift pump is comparatively in- efficient but approximately 35 per cent of the  available compressed air power at the site can  be applied to pumping. Suprisingly high liquid  discharge rates may be obtained in suitable  applications. The theoretical and practical consider- ations of the air-lift pump are evaluated and  a suggested procedure for the emergency design  and construction is outlined. INTRODUCTION.  Sudden inundations of water into mine and development excavations require the immediate  removal of the water if extensive and often  irrepairable damage is to be avoided. Pumps  installed in shafts or tunnels may become un- servicable due to being totally submerged  during the flooding. The emphasis is on rapid
Citation
APA: (1976) The Armor Pipe Roofing Method in Urban Tunnelling
MLA: The Armor Pipe Roofing Method in Urban Tunnelling. The Australasian Institute of Mining and Metallurgy, 1976.