Ventilation Systems As An Effective Tool For Control Of Radon Daughter Concentrations In Mines

Society for Mining, Metallurgy & Exploration
Aladar B. Dory
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
6
File Size:
335 KB
Publication Date:
Jan 1, 1981

Abstract

INTRODUCTION Practical experience in mines with known presence of radon daughters in the mine atmosphere in Canada and elsewhere shows that a very high concentration builds up in an unventilated dead end heading. As Holaday et al1 observed, even a minimal air movement results in a drastic reduction in radon daughter concentration. It is therefore obvious that the main objective of radon daughter control in the working environment is to design the ventilation system providing an optimized flow of fresh air into the workplace, resulting in acceptable climatic conditions and achieving radon daughter concentrations resulting in exposures as low as reasonably achievable. BASIC OBJECTIVES Large mining companies, having extensive material resources and professional expertise, have utilized elaborate electrical modelling in the design of mine ventilation systems as early as 1950 (coal mining industry in Europe) and with the advance of computer modelling techniques, their utilization in ventilation systems design is on the increase. Unfortunately, these methods are usually not available to small mining companies and even the large companies might not achieve the fullest benefit from utilizing them, if proper limiting factors are not considered in the modelling. When an evaluation of a ventilation system of a mine is undertaken in literature, a measure of the amount of air supplied underground per one ton of ore mined is used as an indicator of the efficiency of the ventilation system. Yet, even the greatest amount of air forced into the mine might not result in an acceptable working environment if a proper distribution of this air into individual working places is not achieved. The volume and the age of the air are probably the two most important factors in achieving acceptable radon daughter concentrations in the workplace, but other factors also have to be considered. DIRECTOR MINE - ALCAN, NEWFOUNDLAND FLUORSPAR WORKS ST. LAWRENCE, NEWFOUNDLAND, CANADA Ventilation To illustrate the effects of the design of the ventilation system on the control of radon daughter concentration, let us review the gradual development of the ventilation system of this mine from the earlier years of its development up until its final years of operation. This mine, located near the community of St. Lawrence on the south coast of Burin Peninsula was developed in the late thirties and reached full production by 1942. Unfortunately as was customary at that time, the only source of ventilation was a natural draft. The mine was extremely wet, and no significant attention was initially given to possible health effects of dust. It was not until the mid-fifties, when a number of cases of silicosis had surfaced, that de Villiers and Windish2 observed a significant increase of lung cancer incidence among the miners in comparison to its incidence among the general population of Newfoundland. Suspicions regarding radiation as a cause of the lung cancer were expressed, but it was only in surveys taken in late 1959 and early 1960 that Windish3 and Little4 established the presence of radon daughters in the mine atmosphere in very high concentrations. Windish, de Villiers and Hurley suggested that the most likely source of the radon in the mine was the mine water which dissolved radon during its passage through the granitic country rock in the surrounding geological area. This conclusion was confirmed by analyses of water from various areas of the mine by the Atomic Energy Canada Limited laboratories. The radon values in the samples varied from 4,240 to 12,850 pCi/L5. Following the discovery of the presence of radon daughters in the mine, the company took speedy action to install mechanical ventilation for the mine. The system was not designed as a total unit, but fans were installed rather on a trial and error basis. The basic system installation began in March 1960 and was completed by 1962. It remained basically unchanged with only minor modifications until August 1973 when a wholly new, redesigned ventilation system was implemented. A schematic section of the mine and its ventilation system for the period prior to March 1960 is given in Figure "A", for the period 1960-1973 in Figure "B", and for the period after August 1973 in Figure "C". The ventilation system prior to 1960 is not known. All workings of the mine were ventilated only by natural ventilation. If any measurements of airflows at different or any times of the year ever existed, no records have been preserved. The very minimal natural ventilation was augmented by "blowing" air from compressed air supply lines and exhaust air from drills. It is known that the compressor capacities of the mine were limited and therefore no significant air movement was probably created by the "blowing".
Citation

APA: Aladar B. Dory  (1981)  Ventilation Systems As An Effective Tool For Control Of Radon Daughter Concentrations In Mines

MLA: Aladar B. Dory Ventilation Systems As An Effective Tool For Control Of Radon Daughter Concentrations In Mines. Society for Mining, Metallurgy & Exploration, 1981.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account