Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Comparative Analysis Between Traditional and EC7 Criteria Applied to the Design of Diaphragm Walls Concerning the Ultimate Limit States

    By J. Matos e Silva

    "Abstract The paper refers five examples of executed diaphragm walls with one to five levels of anchorages. For each example a comparison is made between the results of the design using the traditiona

    Jan 1, 2014

  • DFI
    Effect Of Vertical Heterogeneity In Soil Strength On Pile Bearing Capacity Prediction From CPT Data

    By Amaneh E. Kenarsari

    Among the different sources of uncertainty in pile bearing capacity prediction including inherent heterogeneity, measurement and model uncertainties, the inherent heterogeneity of soil properties is o

    Jan 1, 2011

  • DFI
    Analysis Of Static And Dynamic Horizontal Load Tests On Steel Pipe Piles

    By Pastsakom Kitiyodom

    In order to estimate the deformation and load distribution of a single pile subjected to dynamic horizontal load as well as vertical load, a simplified method of three-dimensional numerical analysis,

    Jan 1, 2006

  • DFI
    Route 49 (Penns Neck Bridge) Over Salem River

    By James E. Maccariella

    Replacement of an existing movable bridge with a new low level fixed bridge would not accommodate potential future navigation traffic. In order to replace the existing bridge in a cost effective m

    Jan 1, 2005

  • DFI
    2D And 3D Analysis Of New Austrian Tunnelling Method

    By G. R. Dasari

    New Austrian Tunnelling Method (NATM) has been analysed by Finite Element method in two and three dimensions by Strain Dependant Modified Cam Clay (SDMCC) Model. The effects of construction sequence,

    Jan 1, 1996

  • DFI
    Drilled Piers With Base Preloading By Grouting - 1. Introduction

    By Boleslaw A. Klosinski

    Drilling of a pier hole is accompanied with stress releasing in the surrounding soil and often with loosening of soil at the pier base. In effect the drilled piers are more deformable than driven pile

    Jan 1, 1995

  • DFI
    Lateral Dynamic Response Of Single Inclined Piles

    By Amalia Giannakou

    This paper utilises 3-D finite-element modeling to study the static and dynamic lateral harmonic response of inclined piles, in a homogenous and a non-homogenous soil, modeled as a linear hysteretic m

    Jan 1, 2006

  • DFI
    Bearing Capacity Of Piles Determined By Field Tests ? Synopsis

    By D. M. Milovic

    On the basis of relatively large number of field load tests of piles, the determination of the ultimate bearing capacity have been studied. Using the load settlement curves and the results of the cone

    Jan 1, 2010

  • DFI
    Drilled Shaft Side Shear Capacity In Compressible Materials What Influences Capacity?

    By J. A. Hayes

    For over a decade the Osterberg Load Cell has been successfully used to determine the shear capacities of drilled shafts. Since the test method measures side shear directly, analytical complications d

    Jan 1, 2003

  • DFI
    Effect Of Stabilizing Soft Super-Saline Soil By Vibroflotation ? Synopsis

    By S. F. Fu

    The Charkhan Salt Lake area of the Chaidamu Basin in West China is characterized by soft super-saline soils with very high contents of soluble salts. From the engineering point of view, these saline s

    Jan 1, 2010

  • DFI
    Load-Deformation Based Design of Deep Mixing for Supporting MSE Walls at Kitimat LNG, BC

    By Randy R. Williams, Brian W. Wilson, George M. Filz, Marina S. W. Li

    "Detailed design of an extensive deep mixing (DM) scheme using the Cutter Soil Mixing (CSM) technique was completed for foundation support of mechanically stabilized earth (MSE) walls for Kitimat Liqu

    Jan 1, 2015

  • DFI
    Experiences With Base Grouted Drilled Shafts In The Southeastern United States

    By Steven D. Dapp

    The use of base grouting (tip grouting) to enhance the axial capacity of drilled shaft foundations can achieve improvements in economy and reliability for many types of projects and soil profiles. Rec

    Jan 1, 2006

  • DFI
    Load Test On A Model Pile Driven Into Sand ? Summary

    By A. Mazzucato

    This paper presents the experimental results of driving and load tests on an instrumented pile driven into a test pit filled with fine homogeneous sand.

    Jan 1, 2010

  • DFI
    The Design of Partial Depth Cement Deep Mixing (CDM) Foundation for an Immersed Tunnel

    By J. S. Lee, R. K. Massarsch

    "A 3.2 km long immersed road tunnel forms part of the Busan-Geoje Fixed Link in South Korea, which connects Korea's second largest city Busan, with the island of Geoje. To ensure the water tightness o

    Jan 1, 2015

  • DFI
    Analysis Of Piled Raft Foundation ? Synopsis

    By Gandhi

    Piled raft foundation under uniformly distributed vertical loads has been analyzed using Finite Element Method. The soil is considered to be linear elastic, isotropic, homogeneous. The raft,pile and t

    Jan 1, 1996

  • DFI
    Reduction Of Local Scour Around Cylindrical Bridge Piers Using Upstream Protective Piles

    By A. K. Bhattacharya

    Cylindrical bridge piers are widely used and equations exist that can predict the maximum depth of local scour around such piers. Scour around piers is an undesirable phenomenon, as it requires the fo

    Jan 1, 2009

  • DFI
    An Approximate Nonlinear Analysis Of Vertically Loaded Piled Rafts In Layered Soils

    By Seung-hoon Lee

    The use of piled raft foundations has been considered as an economical alternative to conventional piled foundations because a portion of the applied load is carried by the raft in the design of piled

    Jan 1, 2008

  • DFI
    Large Diameter CIDH Construction In Cohesionless Soils By The Use Of Rotator/Ocsillator Techniques: A Case Study - 116th Avenue Bridge Over The Gila River Phoenix, Az.

    By M. Cornelius

    Drilled shaft construction through caving soils has historically been an uncertain, risky and costly operation. Uncertain, because the zone of caving may or may not be known, risky because the loss of

    Jan 1, 1999

  • DFI
    Bending Strength Of Threaded Micropile Connections

    By Steven R. Musselman

    The bending strength and flexural stiffness of a micropile at its threaded connection is less than its intact strength and may fail due to thread slippage or by fracture through the pin (reduced cross

    Jan 1, 2007

  • DFI
    Analysis Of Pile Behavior In Granular Soils Using DEM

    By Jeremy G. Kress

    We propose the discrete element method (DEM) as a complimentary alternative to analytical solutions and FEM models for the analysis of pile response. DEM is a novel approach to the engineering design

    Jan 1, 2010