Optimization Of Pile Length Using Decision Analysis With Information From Load Tests During Construction
By Jiun-Yih Chen
Pile load tests are regularly used to verify pile capacities. Sometimes, they are used to optimize pile designs. This paper presents a case study based on a real project, in which the information ob
Jan 1, 2009
-
Axial Pile Response Evaluation By Geophysical Piezocone Tests
By Paul W. Mayne
The axial load-displacement-capacity and load-transfer response of deep foundations can be conveniently assessed by geophysical piezocone tests that provide four independent readings with depth, inclu
Jan 1, 2002
-
Lateral Behavior Of Post Grouted Drilled Shafts
By Emad Farouz, Ehab S. Shatnawi, Charles Winter
The increasing demand for small deformations and high-capacity drilled shafts without enlarging drilled-shaft diameters has motivated the development and increased use of a base grouting (BG) techniqu
-
Research On The Interaction Between Pile And Foundation Soil By Boundary Element Method
By Wang Lushuang
This thesis is devoted to the research of the interaction between pile and foundation soil by boundary element method (BEM for short). The interaction is simulated by the interaction between two diffe
Jan 1, 1991
-
Design And Installation Of Pressure-Grouted, Drilled Displacement Piles
By Willie M. NeSmith
The use of drilled (screwed) displacement piles is an emerging sector of the United States deep foundation industry. During installation of these systems, a Ko to Kp environment is created in the mate
Jan 1, 2002
-
Hammer-Grout Piles At The Bronx-Whitestone Bridge
By Ameir Altaee
Unconventional means and methods were utilized to install over 650 contractor-designed micro-piles for the replacement of the Bronx approach to the Bronx-Whitestone Bridge in New York City. The metho
Jan 1, 2010
-
Viscoelastic Finite Element Analysis Of Diaphragm Walls ? Synopsis
By M. Y. Xia
In this paper, based on the Theological tests of the interface between clay and concrete, an interface Theological model is proposed and is used in the finite element analysis which takes soil as visc
Jan 1, 2010
-
Foundation Code8 And Linit 8tatb Partial Factoring - Synopsis
By W. G. K. Fleming
The codification of foundation design and construction is a subject of extensive discussion in Europe and all current code proposals are based on limit state partial factoring. For simplicity, it is c
Jan 1, 1996
-
Driven Piles Hollow Concrete Spun Piles – The Brazilian Experience
"Premissas BásicasCaracterísticas do concreto centrifugado(Spun concrete characteristics)Aplicação em obras de engenharia de fundações(Application engineering works foundations)Logística de fabricação
Jan 1, 2015
-
Inelastic Response Of Extended Pile Shafts In Laterally Spreading Ground During Earthquakes
By Arash Khosravifar
The seismic design of extended pile shafts for the combined effects of dynamic shaking and liquefaction-induced lateral spreading is investigated using nonlinear dynamic finite element analyses (NDA).
Jan 1, 2010
-
Session 15 "Jet Grouting IV"
By Mitsuhiro Shibazki
I can't answer that question but I am looking at Andy, my co-author, and he says we didn't measure it. No movement. If I understand it correctly, how do we handle lateral forces in shear? T
Feb 10, 2003
-
Analysis On The Vertical Bearing Capacity Of Socketed Piles
By Yong Jingrong
Based on the results of several test socketed piles in Sichuan, the mechanism of the deformation for a loaded socketed piles is investigated, and the concept of the socketed effect is proposed. The be
Jan 1, 1991
-
A Seismic Construction Of Piling Head ? Synopsis
By K. Oshima
In Japan, earthquakes are experienced frequently. Many buildings and structures in Japan are supported on pile foundations. For these pile foundations, the joint section between the piles and footing
Jan 1, 2010
-
Towards a Performance-Based Design of Drilled Shafts
By Kam Ng
For bridges or buildings that may be subjected to large vertical and lateral loads, drilled shafts offer an economic foundation solution. While the current drilled shaft design practice is considered
Jan 1, 2013
-
Seasonal Strain Distributions in Full-Scale Energy Foundations (720c13b2-b754-45d9-8b84-e88f10ec05b5)
By Kyle Murphy, John S. McCartney
This paper focuses on the seasonal thermo-mechanical response of two energy foundations installed at the new Denver Housing Authority Senior Living Facility in Denver, Colorado. The two drilled shaft
Jan 1, 2017
-
Sheet Piling Bridge Abutments
By Robert J. Carle
This paper reviews a variety of highway structures which have been built using steel sheet piling as the permanent structural elements of bridge piers, abutments and wingwalls. Those structures built
Jan 1, 1989
-
High Capacity Minicaissons In NYC
By Lawrence F. Johnsen
Six case histories are presented in which tall, slender high rises are supported on high capacity minicaissons. The recent development of a high strength rebar cage has resulted in compressive loads o
Jan 1, 2007
-
Controlling Vibrations From Close-in Pile Driving
By Patrick T, David K. Miller
Driven piles are an effective and cost-efficient deep foundation method; however, when piles are driven near existing buildings and improvements, vibrations must be controlled to non-damaging levels.
-
Assessment Of Safe Load On Piles Using Indian Standard Codeprivate ? Synopsis
By Shenbaga R. Kaniraj
The pile loading tests are generally conducted to assess the safe load on piles in compression. In the Indian practice, the safe load is determined using the pile loading test data and the two criteri
Jan 1, 1996
-
Piled Rafts In Geotechnical Practice - An International Perspective
By Michael W. Neill, O&apos
The performance of foundations that combine the high bearing capacity of rafts (mats) with the settlement reduction capability of piles is described through a summary of 24 case histories. Structures
Jan 1, 2003