Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Presentation #7 - Bi-Directional Static Load Testing - Load Testing High Capacity Piles What Have We Learned?

    By Jorj Osterberg

    550 load tests of up to 150 MN have been completed on driven and bored piles using the Osterberg Load Cell. Because the test measures side shear and end bearing separately, much can be learned about t

    Jan 1, 2001

  • DFI
    A Numerical Study On The Lateral Resistance Of Steel-Concrete Composite Drilled Shafts For Long-Span Bridges

    By Juhyung Lee

    Recently, large diameter drilled shafts are often used for foundations of large-scale marine bridges with high capacity and required to resist lateral loads. Steel casings are essential in supporting

    Jan 1, 2008

  • DFI
    Finite Element Analyses And Cofferdam Excavations

    By Dimitrios C. Konstantakos

    Cofferdam excavations have traditionally been designed with classical design methods that involve direct computations of active or apparent earth pressures. However in contrast to finite element metho

    Jan 1, 2013

  • DFI
    Innovations in Mass Stabilization for Ground Improvement and Environmental Remediation

    By Charles M. Wilk

    "Mass stabilization (MS) is a ground improvement technique that can prepare areas of low bearing strength soil for subsequent infrastructure development. The technique involves mixing binding agents s

    Jan 1, 2015

  • DFI
    Dynamic Load Testing Of Augered Cast-In-Place Piles (Rausche)

    By Frank Rausche

    The more widespread use of Augered Cast-in-Place (ACIP) Piles has generated increased demand for improved quality control measures. These deep foundation elements are often relatively long and slender

    Jan 1, 2001

  • DFI
    The Quality Control Of Deep Foundation ? The New Approach By Non-Destructive Techniques ? Synopsis

    By K. S. Ho

    With the aid of the advanced electronic devices and micro-processors, the quality control of deep foundations can be carried out by Non-Destructive Tests (NDT). Three methods are presented here: the S

    Jan 1, 2010

  • DFI
    7-Foot Diameter Drilled Shafts In Weathered Rock: Design, Load Testing, And Construction

    By Aly M. Mohammad

    The design of large diameter drilled shafts in weathered rock has always presented a challenge to the foundation engineers. Degree of weathering and load transfer mechanism through the rock are essent

    Jan 1, 2003

  • DFI
    Design, Prediction And Performance Of Tied Back Shotcrete Walls Supporting Masonry Hospital Structures

    By Frank Borda

    Two recent projects were completed in Ontario, Canada for major hospital additions that involved excavation support of heritage masonry structures. Conventional continuous caisson wall schemes were re

    Jan 1, 2004

  • DFI
    Suwanee American Cement Plant, Branford, Florida: A Case Study Of Large Diameter Continuous Flight Auger Design Build Foundations

    By Gordon King

    This paper presents a case study of large diameter continuous flight auger (CFA) piles and drilled shafts utilized for foundation support of a series of heavily loaded cement plant structures at the S

    Jan 1, 2003

  • DFI
    Micropiles For Rehabilitation Of Two Existing Structures

    By Jeffrey R. Hill

    This paper discusses the use of micropiles for the rehabilitation of the following two structures: the Milwaukee Auditorium Theatre, in Milwaukee, Wisconsin, and the Cupples Ballpark Lofts, in St. Lou

    Jan 1, 2008

  • DFI
    An Investigation Of Pile Foundations Installed During The Late 19th And Early 20th Century For Re-Use In Building Support

    By Scott M. Doehla

    A proposed rehabilitation of a 200,000 sf, 75-foot high steel-frame building at the former U.S. Navy Yard in Brooklyn, New York required the review of existing foundation data and an investigation of

    Jan 1, 2008

  • DFI
    Session 14 "Deep Mixing Method III"

    By Stefan Dahlin

    The laboratory tests indicated low permeability but as I said, as a rule, the permeability in the field has been found to be higher. A high permeability has also been found when doing back calculation

    Feb 10, 2003

  • DFI
    Vertical Load Carrying Capacity Of Concrete Expanded Base Piles

    By Mustapha Zergoun

    This paper presents the results of load tests to assess the vertical load carrying capacity of concrete expanded base piles, or pressure injected footings, for various projects located near Vancouver,

    Jan 1, 2004

  • DFI
    Structure Monitoring During Underpinning

    By Barry C. Roth

    A Real Time Automated Remote Reading Electrolytic Tilt Monitoring System was effectively deployed for monitoring an existing five story brick building during underpinning, shoring and excavation opera

    Jan 1, 2007

  • DFI
    Design Of The Marine Foundations For The Skyway Project Of The San Francisco Oakland Bay Bridge

    By Gerry Houlahan

    The east span of the 3.5 km long SF-Oakland Bay Bridge is supported by different types of foundations along its span. Starting from the west, its first 460 m section comprising twin concrete box-girde

    Jan 1, 2013

  • DFI
    The Micropile Network: Practice Precedes Theory

    By Gary M. Weinstein

    Micropiles have seen increasing use for foundation support and slope stabilization applications over the past half century. Most often designed and installed in groups of vertical or battered elements

    Jan 1, 2003

  • DFI
    Design, Construction And Testing Of Micro-Piles Used To Support A Concrete Arch Bridge

    By William Auyeung

    Micro-piles are small-diameter, drilled and grouted reinforced piles used for both structural support and in situ earth reinforcement. They were conceived in Italy in 1952, but have become popular in

    Jan 1, 2004

  • DFI
    Founded on Creativity North Dakota’s Four Bears Bridge

    By Terrence R. Udland, Russell D. Call

    "Honored with a DFI 2006 Special Recognition Award, the Four Bears Bridge was constructed across Lake Sakakawea and opened to traffi c in September 2005. The very large lake size and severe winter con

    Jan 1, 2007

  • DFI
    Application of the Cement Deep Mixing Method for Shallow Water Areas Using the CDM-Float Technique

    By Takeo Asanuma, Sachihiko Tokunaga, Hirofumi Taguchi, Yasuhiro Ootsuka, Yosuke Tanaka

    The Cement Deep Mixing Method (CDM Method) is a ground improving method that has been used for mainly offshore sites to strengthen the soft ground below the sea bottom by injecting and adequately mixi

    Jan 1, 2015

  • DFI
    Pier Design And Construction In Water Bearing Soils ? Synopsis

    By C. N. Baker

    The design and construction of drilled piers through water bearing and caving soil conditions are discussed. The need for close cooperation between the design engineer and contractor in both the desig

    Jan 1, 2010