Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Analysis Of Vertical Piles In Granular Soils Subjected To Static Lateral Loading - Synopsis

    By K. Rama Sarma

    Piles are frequently subjected to lateral forces and moments in addition to vertical forces and hence the piles have to be designed for both lateral loads as well as vertical loads. In the design of s

    Jan 1, 1996

  • DFI
    Design And Installation Of Pressure-Grouted, Drilled Displacement Piles

    By Willie M. NeSmith

    The use of drilled (screwed) displacement piles is an emerging sector of the United States deep foundation industry. During installation of these systems, a Ko to Kp environment is created in the mate

    Jan 1, 2002

  • DFI
    Effects Of Permanent And Temporary Loads On Allowable Bearing Capacity Of Piles Subjected To Nagative Skin Friction

    By Mohammad T. Izadi

    Piles are, often, used for transferring load from the super structure through soft consolidating strata onto relatively stiff uncompressible soils. Downward movement of the soft soil strata develops

    Jan 1, 2001

  • DFI
    Evaluation Of Pile Load Test Results

    By Rasin Duzceer

    In this paper, the results of pile load test on 24 piles from twelve sites are presented. The pile load tests were performed on 14 driven and 10 bored piles of varying diameters and lengths installed

    Jan 1, 2002

  • DFI
    Heating and Cooling Structures with Steel Pile Foundations - Closed Loop Standing Column Well Technology (df25801f-7df6-457c-ab18-569c2a6ce07f)

    By Paul Suver

    "The closed loop standing column well (CLSCW) system uses a closed circuit of water to develop the same thermal heat exchange characteristics that are achieved from traditional open circuit standing c

    Jan 1, 2017

  • DFI
    Experiences And New Developments In Offshore Foundation

    By Franz-Werner Gerressen

    As alternative energy industries pick up speed internationally, and as government regulation and restriction limit the use of impact hammers due to environmental limitation from construction induced n

  • DFI
    Keynote Lecture 5: Giovanni Lombardi Grouting of Rock Masses

    By Giovanni Lombardi

    In order to get a clear overview of the grouting works carried out, to avoid misinterpretations of the data and functions shown on the display of the grout monitoring device, it is recommended to keep

    Feb 10, 2003

  • DFI
    Using Dynamic Pile Testing To Overcome Surprising Soil Variations

    By H. (Sam) Salem

    A site investigation for a wide and tall hotel building, in the San Juan Bay area, Puerto Rico, indicated a soil profile of silty clay on sand, soft and loose enough to require piled foundations. The

    Jan 1, 2008

  • DFI
    Heating And Cooling Structures With Steel Pile Foundations Closed Loop Standing Column Well Technology

    By Paul Suver

    The closed loop standing column well (CLSCW) system uses a closed circuit of water to develop the same thermal heat exchange characteristics that are achieved from traditional open circuit standing co

  • DFI
    Seismic Design Of Micropile Foundation Systems

    By Leo Panian

    Over the last decade, drilled and post-grouted micropile foundations have come to be increasingly relied upon for resisting seismic loads in building foundations on the West Coast. Micropiles have bee

    Jan 1, 2010

  • DFI
    Cased CFA Pile – An Alternative Piling Method – A Chance for Technical and Economical Solutions

    By John R. Grillo, Gordian Ulrich, Franz-Werner Gerressen

    Most geotechnical construction professionals are aware of piling using hydraulic drill rigs and the so-called Kelly drill mode. Kelly drilling has many advantages as it can work with a wide range of t

    Jan 1, 2019

  • DFI
    Deep Excavation And Earth Retaining Structure ? Synopsis

    By S. Y. Zhou

    Excavation with earth retaining is one of the main technological means in deep foundations and underground engineerings. Several construction methods which have been used in China are introduced here

    Jan 1, 2010

  • DFI
    Use Of Cone Penetration Test (CPT) Results For Accurate Assessments Of Pile Capacities

    By Anand J. Puppala

    This paper provides information on various evaluation studies conducted to assess the CPT based interpretation methods. Salient findings from these evaluations are summarized. Additionally, a comprehe

    Jan 1, 2002

  • DFI
    Settlement Control Of A Road Embankment Using Vertical Drains

    By Wei Tu

    A grade separation was required to allow uninterrupted traffic crossing for a busy rail spur and a county road. The grade separation was achieved by creating a 30-foot (9-meter) high embankment that

    Jan 1, 2009

  • DFI
    Design Practice Of Circular Diaphragm Wall Structure With Large Diameter ? Synopsis

    By X. Y. Hou

    The design practice of several circular underground projects with large diameter is summarized. By taking the advantages of load-bearing of circular structure, a rational annular tensile bar support s

    Jan 1, 2010

  • DFI
    On The Ultimate Capacity And Radial Stress Distribution Of Driven Piles In Sands

    By E. Ulrich Klotz

    It is difficult to predict accurately the capacity of driven piles in sand. In practice, this uncer­tainty either leads to conservative designs if the capacity is under-predicted, or worse, if the cap

    Jan 1, 2002

  • DFI
    Driven Piles Hollow Concrete Spun Piles – The Brazilian Experience

    "Premissas BásicasCaracterísticas do concreto centrifugado(Spun concrete characteristics)Aplicação em obras de engenharia de fundações(Application engineering works foundations)Logística de fabricação

    Jan 1, 2015

  • DFI
    Behaviour Of Model Pile Group Under Axial Monotonic Loading

    By A. Le Kouby

    We present in this paper the results of a parametric study carried out in a calibration chamber on instrumented model piles. The aim is to point out group effect on piles within a group through their

    Jan 1, 2006

  • DFI
    The Choice between HSDT and RLT: Selection Criteria for Concrete Pile Testing

    By P. Middendorp, Gerald E. H. Verbeek

    "INTRODUCTIONStatic Load Testing (SLT) is generally considered the pile testing method that provides the de-facto answers regarding pile capacity and load-deflection behavior. However, as this testing

    Jan 1, 2006

  • DFI
    Time Effect Of Bearing Behavior Of Bored Pile Group In Un-Saturated Silty Soil ? Synopsis

    By J. L. Liu

    Long-term maintained load test on the bored pile group in unsaturated silty soil has been carried out. And the research on the time effects of bearing behavior of pile group has been done by the metho

    Jan 1, 2010