Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Use Of Installation Effort To Evaluate And Design Drilled Displacement Piles In Fine-Grained Soils

    By W. Morgan NeSmith

    A drilled displacement pile program was utilized for the expansion of an existing power plant in Cohasset MN adjacent to the Mississippi River. The drilled displacement (DD) pile is an innovative foun

    Jan 1, 2008

  • DFI
    Analyses Of Dynamic Increasing Energy Load Test On Deep Foundations

    By Silvana B. Foá

    Results from full-scale loading tests showed the use of the dynamic increasing energy test (DIET) to verify the capacity of deep foundations. This method allows the measurement of dynamic resistance -

    Jan 1, 2002

  • DFI
    New Load Testing Device

    By Jorj O. Osterberg

    This paper is for presentation at the 14th Annual Members Conference of the Deep Foundations Institute held at the Hyatt Regency Hotel, Baltimore Maryland on October 10, 1989. This is an introduct

    Jan 1, 1989

  • DFI
    Determination Of The Load-Displacement Characteristics Of Single Pile In Soft Soil ? Synopsis

    By Z. C. Chen

    Based on the analysis of load test data of long floating piles in soft soil regions, the expressions of load-transfer function of pile shaft and tip for soft soils are presented in this paper, and the

    Jan 1, 2010

  • DFI
    A General Formula To Determine The Allowable Pile Bearing Capacity In Case Of Negative Skin Friction ? Summary

    By Cornelis Van Der Veen

    Foundation piles, partly passing through unconsolidated compressible layers, suffer a downward drag that is called negative skin friction. The negative skin friction depends on the movement of the sur

    Jan 1, 2010

  • DFI
    Behavior Of Pile Foundation Under Impact Lateral Loads

    By Hajialilue Bonab M.

    The soil-pile interaction under lateral impact loads is not yet completely well known. Many tests on single piles under static lateral loads in centrifuge have been performed and P-y curves have been

    Jan 1, 2002

  • DFI
    Numerical Analysis Of The Pile-Enhanced Raft Of The Queen Elizabeth II Conference Centre In London, UK

    By Trevor I. Addenbrooke

    Stress reducing piles were used for the first time at the Queen Elizabeth II Conference Centre near the Palace of Westminster in London, UK. The inclusion of these piles directly beneath heavily loade

    Jan 1, 2002

  • DFI
    On The Ultimate Capacity And Radial Stress Distribution Of Driven Piles In Sands

    By E. Ulrich Klotz

    It is difficult to predict accurately the capacity of driven piles in sand. In practice, this uncer­tainty either leads to conservative designs if the capacity is under-predicted, or worse, if the cap

    Jan 1, 2002

  • DFI
    Wireless Site Data Collection In Construction And Its Impact On The Business Process

    By Jason N. Scott

    It is now possible using low-cost wireless technology and rugged hand-held devices to record data on site electronically and for that data to be instantly available to others. This could potentially e

    Jan 1, 2006

  • DFI
    A Coupled FE-BE Formulation For The Prediction Of Vibrations Due To Vibratory And Impact Pile Driving

    By H. R. Masoumi

    This paper presents a numerical model for the prediction of free field vibrations due to vibratory and impact driving. As the focus is on the response in the far field, where deformations are relative

    Jan 1, 2006

  • DFI
    The Practical Application Of Pile Reuse At Bow Bells House, City Of London

    By Justin Phillips

    The redevelopment of Bow Bells House in London has thrown up a number of challenges that will increasingly be faced by developers of congested sites. In the context of pile reuse this paper examin

    Jan 1, 2008

  • DFI
    Compaction-Induced Lateral Earth Pressures And Vertical Shear Forces Acting On Non-Moving Retaining Walls

    By George M. Filz

    Restrained basement walls and unrestrained but massive concrete walls on rock foundations experience very small movements in response to lateral earth pressures. Such walls are often designed using at

    Jan 1, 2003

  • DFI
    Interpretation Of Full Scale Horizontal Pile Loading Tests In Sand Analysis Of P-Y Curves

    By Ali Bouafia

    Five full-scale horizontal loading tests of piles carried out by the LCPC in France are interpreted in order to analyse P-Y load-transfer curves. The experimental piles are either bored or jacked into

    Jan 1, 2002

  • DFI
    Performance Of Drilled Displacement Piles In The Midwestern United States

    By W. Morgan NeSmith

    Drilled displacement (DD) piles often develop significantly larger unit shaft resistance values than other drilled or augered pile systems in coarse grained materials. Minimal vibration and limited sp

    Jan 1, 2009

  • DFI
    Optimization Of Pile Length Using Decision Analysis With Information From Load Tests During Construction

    By Jiun-Yih Chen

    Pile load tests are regularly used to verify pile capacities. Sometimes, they are used to optimize pile designs. This paper presents a case study based on a real project, in which the information ob

    Jan 1, 2009

  • DFI
    Negative Drag Reduction On Spliced Piles - An Insitu Study - Synopsis

    By Gopal Ranjan

    An insitu prtotype study on precast driven spliced piles in soft marine clay deposit has been carried out to study negative drag. The drag is generated by loading the ambient clay. For reduction in ne

    Jan 1, 1996

  • DFI
    The Cosmopolitan Resort & Casino, Las Vegas, NV Specialty Foundation Work Under Extreme Conditions

    By Lawrence Piccagli

    This past spring of 2006, BENCOR installed the concrete reinforced diaphragm walls for the COSMOPOLITAN RESORT & CASINO in Las Vegas, Nevada. The project highlights include the excavation of approx. 3

    Jan 1, 2007

  • DFI
    Practice to Reduce Ground Displacement in Deep Mixing Work

    By Kozo Takeda, Arashi Shimano

    "Dry Jet Mixing (DJM) technique is widely known as soil mitigation technique with small ground displacement during installation comparing with other techniques. Some projects involving sensitive struc

    Jan 1, 2015

  • DFI
    St. Anthony Falls, I-35w Bridge Drilled Shaft Load Test Program

    By Jeffrey A. Gebhard

    As part of the design and construction of the new St. Anthony Falls I-35W Bridge, a full-scale load test was conducted on a 6 1/2-foot diameter drilled shaft in the St. Peter Sandstone. This load tes

    Jan 1, 2009

  • DFI
    Information Technology And The Foundation Industry

    By Andreas Massarsch

    Information Technology, IT, is rapidly affecting all aspects of private life and how professional activities are conducted. Probably the most important development is the Internet, which makes it poss

    Jan 1, 2002