Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
Influence Of Diameter On The Bearing Capacity Of Lateral Loaded Drilled ShaftBy Bin Zhang
Drilled shafts are a popular type of foundation for transportation applications. They feature the advantages of providing high bearing capacity and generating low construction noise. Advancements in
Jan 1, 2007
-
Resistance Factors For Lateral Design Of Drilled Shafts Supporting Sound WallsBy Ke Yang
Drilled shafts are widely used as foundation system for sound walls to resist lateral loads. The design method based on the ultimate lateral capacity, such as Broms method, is often used for sound wal
Jan 1, 2007
-
A Small Diameter Vibration Pile With Soil CompactionBy Miklós Kovács
A new type of the cast in situ piles is introduced. The installation of the new pile is based on a pushing in/gaining back procedure. A temporarily closed tip element with square shaped cross-section
Jan 1, 2002
-
Dewatering Practice For Deep Basements In HawaiiBy Masanoub R. Fujioka
A brief discussion of the methodologies involved in dewatering practices, particularly as used in Hawaii in coralline formations. A description of early dewatering practices includes a number of case
Jan 1, 1986
-
Horizontal Resistance Behavior Of Pile With Wings In SandBy Wen Songlin
This paper presents an experimental program to investigate the behavior of a pile with wings under horizontal loads in sand at laboratory. The work focused on evaluating the lateral resistance behavio
Jan 1, 2007
-
The Test on Effect of Polyanionic Cellulose on Process of Filtrate Loss of Low Solid-Phase Drilling Fluid (cdc8479e-b761-4427-8d26-4088be3d5ab5)By Ping Yang, Tian-bin Li, Min-hui Wu
"The process of filtrate loss of low solid-phase drilling fluid at different content of polyanionic cellulose is investigated by the standard filtration test. The test results showed that when time of
Jan 1, 2017
-
Rapid Load Testing In GermanyBy Marcel Bielefeld, Joost Bakker, Rob van Dorp
Pile load testing can be performed by a static, rapid or high strain dynamic (generally designated as dynamic) testing method. The static load test is often considered the “gold standard” of testing w
May 1, 2022
-
Deep Compaction Of Saturated Loess By Means Of Sand-Gravel Piles ? SynopsisBy Z. G. Lin
In Xian, China, compaction by means of soil (or lime-soil) piles is one of the effective methods widely used for densifying loess and eliminating its collapsibility. However, as a result of groundwate
Jan 1, 2010
-
Non-destructive Testing Of Unknown Bridge Foundation Lengths Using Parallel Seismic TestingBy Chetan D. Savani, Mike K. Muchard
The necessity to evaluate undocumented foundation lengths is essential in assessing the useable life, need for scour protection, retrofitting, or full reuse of existing bridge foundations. For this pu
-
Case History: Effect Of Plastic Clays On The Behavior Of APGD Piles In Central FloridaBy Amr M. Sallam
In recent years, with the increase of the number of high-rise buildings that are proposed and being built in Central Florida especially in Downtown Orlando, Augered Pressure Grouted Displacement (APGD
Jan 1, 2006
-
Harmonization of Execution Codes: Overview of Standardization for US TransportationBy Silas C. Nichols
"Abstract Piling and deep foundations are a staple for transportation projects in the United States (US). Driven or bored piles have been used for everything from support of bridge foundations and ret
Jan 1, 2014
-
Sleeved Pile Foundations For The W. Seattle - Harbor Islands Swing Bridge And The Seattle Access ProjectsBy Kent C. Werle
This brief discusses the installation and application of sleeved piles of two different types for two different projects, the W, Seattle to Harbor Island Swing Bridge Project and the Seattle Access Pr
Jan 1, 1990
-
Contribution of Inner Frictional Resistance to Bearing Capacity of Open-Ended PilesBy Janaka J. Kumara, Takashi Kurashina, Yoshiaki Kikuchi, Takahiro Yajima
"The inner frictional resistance of open-ended piles depend heavily on the degree of soil plugging. Many factors including pile diameter, relative density and end conditions of the piles influence the
Jan 1, 2017
-
Comparative Analysis Between Traditional And EC7 Criteria Applied To The Design Of Diaphragm Walls Concerning The Ultimate Limit StatesBy J. Matos e Silva
The paper refers five examples of executed diaphragm walls with one to five levels of anchorages. For each example a comparison is made between the results of the design using the traditional crit
Jan 1, 2002
-
Consideration on Liquefaction Resistance of Ground Improved by the Sand Compaction Pile MethodBy Kazunori Matsushita, Masaru Sakakibara, Kenji Harada, Naotoshi Shinkawa, Mitsuo Nozu
The Sand Compaction Pile (SCP) method has been widely used as a typical countermeasure against liquefaction in Japan, and its effectiveness has been confirmed in many case histories of damages caused
Jan 1, 2017
-
The Waterloo Barrier - A Sealable Joint Steel Sheet Piling For Groundwater Control And Remediation - Presented At The Deep Foundations Institute Annual Meeting & Conference Toronto, Ontario, October 15-17, 1997 - SummaryBy Murray Gamble
A new type of groundwater cutoff wall has been developed at the University of Waterloo. The Waterloo Barrier? is a steel sheet piling system that incorporates a sealable cavity at each interlocking jo
Jan 1, 1997
-
-
Effect of Grid-Form Deep Mixing Walls to Prevent Liquefaction Damage of Small HousesBy Shoichi Tsukuni, Akihiko Uchida, Kazuo Konishi
"In order to investigate the effect of grid-form deep mixing walls as a countermeasure for liquefaction damage to roads and private houses in Urayasu, Japan, three dynamic centrifuge model tests were
Jan 1, 2015
-
Use Of Anchors In Floors Of Large Drydocks And Wagon Tipper Sheds ? SynopsisBy W. H. Liu
The stability of floors of large drydocks and wagon tipper sheds at coal terminals is an important matter but quite difficult to solve. Anchors can be used to join floors to foundations thus ensuring
Jan 1, 2010
-
Analysis Of Driving Stress Measured In The RC Long PileBy Yu Zhenquan
At the construction site of Bao Shan Iron &. Steel Mill in Shanghai, lots of RC driven piles with length of 50 to 60m were applied. The most unfavourable distribution of stress along the pile shaft wa
Jan 1, 1991