The Autowarning Telltale: A New Safety Monitoring Device for Pillar Extraction OperationsBy David Bigby
Room and pillar mining with full pillar extraction is one of the most hazardous systems of underground coal mining, a significant hazard being the potential for sudden goaf override. The Autowarning
Jan 1, 2011
-
Some Technical Considerations When Mining Under Bodies Of WaterBy John W. Fredland
Conducting mining operations under a body of Water can create hazardous conditions for miners. The potential for a sudden inrush must be considered and abnormal ground control conditions can be encoun
Jan 1, 1982
-
Potential Problems Related To Mining Under Or Adjacent To Flooded WorkingsBy Stanley J. Michalek
Good planning is critical to operating a safe and efficient mining operation. As the shallow coal scams become depleted, attention turns toward deeper mineable seams or remnant coal reserves. It is be
Jan 1, 2000
-
Changes In Seismic Measurements With Blast Induced Fracturing: A Field ExperimentBy Clifford J. Roblee
In this paper, various seismic indicators are evaluated for ability to discern fractures induced into a rock mass by blasting. This is accomplished by presenting results from in situ crosshole seismic
Jan 1, 1989
-
The Formation And Effects Of Transient Abutment Stress During Nonuniform Face AdvanceBy George J. Karabin
Since the inception of a qualitative pressure arch theory by Haak4 in 1911, much work has been done in an effort to apply this concept to underground mining. It has been used in both longwall and room
Jan 1, 1982
-
Laboratory Testing of Rib StrapsBy E. Bane Kroeger
Rib failure is a hazard that has resulted in many injuries and fatalities in underground coal mines, especially in soft coal seams. Conventional rib control methods including rib boarding, shotcreting
Jan 1, 2004
-
Application of Yieldable and Cuttable Pump Crib in Longwall Recovery RoomBy Quanzhong Gu
Stability of a pre-exnacted recovery room plays a vital role when longwall face approaches and during a longwall face move. In an attempt to extend the application of pumpable cribs into recovery room
Jan 1, 2004
-
Application Of Ground Penetrating Radar To Evaluate The Extent Of Polyurethane Grout Infiltration For Mine Roof Control - A Case StudyBy William Monaghan
Over the period 2000 to 2003, roof falls have accounted for 4 to 14% of the fatalities in underground mining operations. The National Institute for Occupational Safety and Health (NIOSH) is conducting
Jan 1, 2004
-
Elasto-Plastic Finite Element Structural Stability Analysis Of Room And Pillar Mine Workings (1726bb0c-5e63-4f04-a636-538432c37ec9)By S. Bensehamdi
An advanced elasto-plastic finite element model adopting a modified Von Mises yielding criterion was used to simulate progressive failure of the rock strata surrounding a room and pillar mine structur
Jan 1, 1992
-
Computer Modeling Of Yield Pillar Behavior Using Post-Failure CriteriaIn this paper, the plastic increment theory was applied in a 2-D finite element model, and a generalized Von Mises yielding criterion adopted to simulate the progressive failure of coal pillars. Exten
Jan 1, 1988
-
Performance of Various Standing and Cribless Tailgate Support Configurations in a Large Eastern Coal MineBy Gregory M. Molinda
Difficult mining conditions in deep western U.S. Iongwalls have necessitated the use of novel tailgate support systems. Extreme ground movement in these yielding gate systems has caused operators to u
Jan 1, 1997
-
Analysis of Roof Falls at and Recommendation of Roof Control Plansfor Rofomex Posphate MineBy Jinsheng Chen
For underground openings, many factors can cause roof failure and thus roof falls. The most common factors related to Mother Nature are weak roof lithology, geological structures, and an abnormal in-s
Jan 1, 2011
-
The Structural Response Of A Steel Lattice Transmission Tower To Mining-Related Ground MovementsBy Robert W. Bruhn
A 125 foot high steel lattice frame tower supporting a 500 kV EHV transmission line and located over the gateroads of a longwall mining operation was subjected to ground movements from the mining of a
Jan 1, 1990
-
Risk Assessment Of Geotechnical Factors Associated With Underground Thick Seam Mining MethodsBy Bruce K. Hebblewhit
Australia is well endowed with extensive reserves of thick underground coal scams, particularly in the range of 4.5m to 9m thicknesses. (For the purposes of this paper, thick scams are defined as bein
Jan 1, 2001
-
Full-face Pressure Monitoring in Medium-Weak Roof ConditionBy Syd S. Peng
Full-face shield leg pressures in a longwall panel for a three-month period were collected and analyzed. The pressure data were presented in the following forms: full- panel full-face shield pressure,
Jan 1, 1997
-
Ground Control Worker Safety During Extended Cut MiningBy Roy H. Grau
The trend in underground room-and-pillar cod mining is to employ remote-control continuous mining machines to take extended cuts of 40 A or more. Roof fall safety hazards to the mine worker associated
Jan 1, 1997
-
Investigation into the Extent and Mechanisms of Gloving and Un-mixed Resin in Fully Encapsulated Roof BoltsEffective strata control, utilising fully encapsulated roof bolts, is dependent on the installed quality of the reinforcement elements. One mechanism by which fully encapsulated roof bolts may become
Jan 1, 2003
-
Ground Control Problem Associated with Longwall Mining of Developed PillarsBy T. N. Singh
Board and pillar system of mining has beer, practised in India in view of abundant availability of cheap labour force, low investment and quick return. Subsequently, selective mining from thick seems
Jan 1, 1984
-
Advances in Remote Sensing Techniques for Monitoring Rock Falls and Slope Failures (17th CONFERENCE ON GROUND CONTROL IN MINING)By J. M. Girard
Ground control problems at surface mining operations can occur for a variety of reasons. Stress, gravity loading, rock strength, geology, pore pressure, weather effects, underground workings, and many
Jan 1, 1998
-
Mobile Roof Support For Retreat MiningBy H. Gene Wilson
Mobile Roof Supports (MRS) look similar to a longwall shield on crawler tracks. The MRS units offer a safe, productive method of extracting the 40% to 60% product left normally unrecovered in room and